XIA Cai-chu, XU Ying-jun, WANG Chen-lin, et al. Calculation of air leakage rate in lined cavern for compressed air energy storage based on unsteady seepage process[J]. 2021, 42(7): 1765-1773.
XIA Cai-chu, XU Ying-jun, WANG Chen-lin, et al. Calculation of air leakage rate in lined cavern for compressed air energy storage based on unsteady seepage process[J]. 2021, 42(7): 1765-1773.DOI: 10.16285/j.rsm.2020.1385.
To evaluate the air tightness of lined cavern for compressed air energy storage
a kind of unsteady seepage equation considering the influence of air leakage and porosity of concrete lining in the cavern is derived based on seepage flow theory of porous media
and an approximate analytical solution for approximate calculation of air pressure in the cavern is given. To solve this kind of nonlinear parabolic equation accurately
an unconditional stable implicit difference scheme with second order accuracy is constructed by using finite difference method. The results show that
compared with the traditional air leakage estimation formula based on the steady seepage theory
the air leakage calculated considering unsteady flow process of air is slightly smaller. When the permeability of concrete lining with a thickness of 0.5 m is less than 6×10?20 m2
the percentage of air leakage within 24 hours in a compressed air energy storage cycle is less than 1%
ordinary impermeable concrete cannot meet the requirements of air leakage control
and special sealing measures are thus needed. The air leakage percentage of compressed air energy storage cavern is related to lining permeability
air storage pressure
lining thickness. The lower the permeability is
the larger the gas storage pressure is
the larger the lining thickness is
the smaller the air leakage percentage is
and the control effect of lining thickness on gas leakage decreases with the increase of lining thickness.