LEI Xue-wen, DING Hao, WANG Xin-zhi, et al. Experimental study of consolidation properties of calcareous silt[J]. 2021, 42(4): 909-920.DOI: 10.16285/j.rsm.2020.0993.
Due to the effect of sorting by hydraulic dredger fill
the foundation of dredged coral reef in the South China Sea contains fine calcareous silt interlayer with uneven thickness. Compared with coarse-grained calcareous sand
calcareous silt presents higher compressibility
lower bearing capacity and larger settlement deformation
which adversely affect the safety of buildings on coral reefs. In this paper
the characteristics of primary and secondary consolidation settlement
consolidation time and consolidation rate of calcareous silt were obtained through laboratory consolidation tests
for better understanding the engineering properties of calcareous silt and calculation of coral reef foundation settlement. The calcareous silt shows 0.03?0.37 MPa?1 of the compression coefficient and 6.67?54.79 MPa of the compression modulus. Compression coefficient is directly proportional to moisture content and inversely proportional to dry density. Compression coefficient lower than 0.1 MPa?1 and compression modulus more than 20.0 MPa occurs in moderately dense and dense calcareous silt with water content of less than 15% as low compressibility soil
but loose calcareous silt is moderately compressible. Compared with quartz sand under the same dry densities and moisture contents
the compression coefficient of quartz sand is higher than that of calcareous silt
while the compression modulus is lower than that of calcareous silt. Under the same dry density and water content
both Hangzhou Bay silt and calcareous silt show moderate compressibility. However
the compressive modulus of calcareous silt is slightly larger than that of Hangzhou Bay silt
and its compressive coefficient is slightly smaller. When the load exceeds 200 kPa
the degree of consolidation of calcareous silt reaches 0.95 in the first 5 hours of the consolidation test. Therefore
it suggests 24 hours for the consolidation time of calcareous silt under loading less than 200 kPa but 5 hours under loading greater than 200 kPa for the testing efficiency.