GAO Meng, ZHANG Zhi-song, WANG Chong-ge, et al. Field test on vibration isolation performance
by WIB-Duxseal under vertical excitation[J]. 2021, 42(2): 537-546.
GAO Meng, ZHANG Zhi-song, WANG Chong-ge, et al. Field test on vibration isolation performance
by WIB-Duxseal under vertical excitation[J]. 2021, 42(2): 537-546.DOI: 10.16285/j.rsm.2020.0898.
The vibration induced by human activities such as rail traffic
power machine
blast construction and pile driving could seriously influence the normal use of adjacent buildings
the production and use of precision instruments
and the normal production and life of human beings. The control of environmental vibration has become a research focus of soil dynamics. In this paper
a newly designed combined vibration isolation barrier
i.e.
wave impeding block (WIB) with incorporation of Duxseal (DXWIB)
is proposed to reduce the ground vibrations
and the isolation performance is evaluated by field experiment under harmonic vertical excitation within 0–3 s. Through a set of tests
the amplitude and mean value of ground vibration acceleration and displacement with different embedded depths
DXWIB thicknesses
excitation forces and excitation frequencies are obtained and compared. The corresponding curves of amplitude attenuation ratio are drawn. The test results show that: compared with vibration in the horizontal direction
the isolation effect of DXWIB on ground vertical vibration is better. The vibration isolation efficiency of DXWIB barrier varies unevenly with the distance. When DXWIB is embedded in the foundation
the attenuation coefficient of surface displacement amplitude is less than 1. Compared with the influence factors such as DXWIB thickness
excitation force and excitation frequency
the embedment depth of DXWIB has the most significant influence on the vibration isolation effect
and there is a best buried depth and a critical thickness. DXWIB can improve the characteristics of WIB only for low-frequency vibration damping below 10 Hz
and increase the frequency bandwidth of vibration damping. From the experimental data
it has good vibration isolation effect at 5–70 Hz.