JI Wei-wei, KONG Gang-qiang, LIU Han-long, et al. Field tests on thermal response characteristics
of the tunnel invert in soft plastic loess area[J]. 2021, 42(2): 558-564.
JI Wei-wei, KONG Gang-qiang, LIU Han-long, et al. Field tests on thermal response characteristics
of the tunnel invert in soft plastic loess area[J]. 2021, 42(2): 558-564.DOI: 10.16285/j.rsm.2020.0814.
economical and efficient geothermal heat exchange techniques. It can integrate both the anti-freezing and heat preservation for tunnel. Based on the Yinchuan-to-Xi′an high-speed railway tunnel located in loess region
the heat exchange tubes are placed in series in the tunnel invert
and the ground source heat pump system has been built. The heating system is operated under different input powers as well as the inlet and outlet temperature
and the temperature and stresses of the inverted arch are measured. The thermal response characteristics of the tunnel under difference input powers are discussed and analyzed
including heat transfer capacity and thermal induced stresses
etc. Under this field test condition
the results show that the temperature of the inverted arch of tunnel has increased by 4.2℃ and 7.1℃ under 0.5 kW and 1.0 kW input power
respectively. With the increase of water temperature
the invert temperature increases slightly in a short period of time. When the heat propagation path has stabilized
the invert temperature finally presents a linear relationship. The increment of axial stress of the inverted arch of tunnel is larger than that of the longitudinal stress. The axial stresses are 1.15 and 1.29 times of longitudinal stresses under 0.5 kW and 1.0 kW input power