ZHANG Lei, HAI Wei-shen, GAN Hao, et al. Study on bearing behavior of flexible single pile subject to
horizontal and uplift combined load[J]. 2020, 41(7): 2261-2270.
ZHANG Lei, HAI Wei-shen, GAN Hao, et al. Study on bearing behavior of flexible single pile subject to
horizontal and uplift combined load[J]. 2020, 41(7): 2261-2270.DOI: 10.16285/j.rsm.2019.1522.
In order to study the bearing behavior of a flexible single pile under combined horizontal and uplift loading
two groups of structural testing
comprised of 6 pile models in total have been carried out. The results show that for a flexible single pile
pre-applied uplift load with a magnitude smaller than half of pure uplifting capacity(Tu1) lead to significant improvement of ultimate horizontal bearing capacity
achieving greater horizontal resistance compared to pure ultimate horizontal bearing capacity (Hu1) Additionally
it has been observed that this horizontal bearing capacity increases initially but decreases subsequently under further increasing uplift load. This load increasing results in reduction of bending moment and soil resistance whilst degrades horizontal stiffness
and consequently
the horizontal displacement of pile increases initially but decreases subsequently under resultant effect. The ultimate uplift bearing capacity of a flexible single pile could be improved under pre-applied horizontal loads not exceeding 0.5Hu1
mainly attributed by increasing the average side friction of pile within the distance of 10 times the diameter of pile below the ground surface. This capacity is strengthened under larger horizontal load
and when this load reaches 0.5Hu1
the magnitude is increased by 17.1% compared with Tu1. This behavior could be taken into account with respect to pile design. The precision of test results has been verified by theoretical analysis
and a formula for calculating the ultimate uplift bearing capacity of flexible single pile under combined loads has been proposed. The corresponding analysis results have achieved good agreements with testing data and the error is less than 6%.