HAN Bing, LIANG Jian-wen, ZHU Jun. Effect of lenticle on seismic response of structures in deep water-saturated poroelastic soft site[J]. 2018, 39(6): 2227-2236.
HAN Bing, LIANG Jian-wen, ZHU Jun. Effect of lenticle on seismic response of structures in deep water-saturated poroelastic soft site[J]. 2018, 39(6): 2227-2236.DOI: 10.16285/j.rsm.2016.1963.
A lenticle existing in engineering site affacts significantly on the earthquake ground motion. There exists obvious difference between the seismic response of water-saturated poroelastic site and the corresponding dry site. However
there are few studies in literature on influence of lenticle on seismic response in deep water-saturated poroelastic soft site up to now. Using finite element and indirect boundary element coupled method (FEM-IBEM)
this paper investigates the effect of width
thickness and embedded depth of a lenticle on dynamic structural response by the nonlinear dynamic saturated soil-structure interaction model
and particularly analyzes the effect of dynamic coupling effect between solid frame and pore water. The lenticle width
thickness and embedded depth show different effects on the structural response
resulting in obvious difference with those of a lenticle in dry site. The dynamic coupling effect between solid frame and pore water has significant effect on seismic response of the structure.