GONG Xiao-nan, SUN Zhong-ju, YU Jian-lin. Analysis of displacement of adjacent buried pipeline caused by ground surcharge[J]. 2015, 36(2): 305-310.DOI: 10.16285/j.rsm.2015.02.001.
Ground would settle while ground is subjected to surcharge loads. The deformation or break would happen in the walls of the pipelines in the ground due to the settlement. This paper focuses on the effects of ground surcharge on adjacent buried pipelines. A calculation model is established with the theory of Winkler elastic foundation short beam and Boussinesq basic formulas
taking into account the impact of subsoil deformation induced by ground surcharge on pipelines. The solution is derived with the finite difference method. Consequently
cases are performed under various loads
location of the load
geologic condition
pipeline depth
diameter and stiffness of pipeline as well as property of soil. Results show that: after increasing to a certain threshold
the pipeline diameter and the coefficients of foundation bed would have a relatively small impact on the pipeline maximum displacement. However
the buried pipeline deforms significantly as the burial depth decreases. As expected
the maximum displacement of pipeline decreases while the pipe stiffness increases and the location of ground surcharge loads pose large effect on buried pipelines. So it is necessary to consider the surcharge loads and make a reasonable protective measure for buried pipelines.