江苏上上电缆集团有限公司,溧阳 213300
[ "1987—,女,高级工程师研究方向为核电站用低烟无卤阻燃电缆、耐火电缆E-mail:wlp0460@163.com" ]
收稿:2025-08-06,
修回:2025-09-17,
录用:2025-11-05,
纸质出版:2025-11-25
移动端阅览
王丽萍, 金华东, 梁福才. 核电站用耐火电缆选型与结构优化[J]. 电线电缆, 2025, 68(11): 49-54
WANG L P, JIN H D, LIANG F C. Selection and structural optimization of fire resistant cables for nuclear power plants[J]. Wire & Cable, 2025, 68(11): 49-54
王丽萍, 金华东, 梁福才. 核电站用耐火电缆选型与结构优化[J]. 电线电缆, 2025, 68(11): 49-54 DOI: 10.16105/j.dxdl.1672-6901.20250177.
WANG L P, JIN H D, LIANG F C. Selection and structural optimization of fire resistant cables for nuclear power plants[J]. Wire & Cable, 2025, 68(11): 49-54 DOI: 10.16105/j.dxdl.1672-6901.20250177.
为明确核电站用耐火电缆的特性以支撑其选型及生产制造,通过分析其种类、安全分级、质保等级、结构设计,对比不同耐火试验标准(如 GB/T 19666—2019、BS 6387: 2013 等),并开展结构验证试验探究结构对性能的影响。分类上,核电站用耐火电缆主要包括耐火低压电力电缆、控制电缆、测量电缆等,安全分级有 1E 级、非 1E 级等,质保分级多为 Q2、Q3 等;结构上,耐火层以云母带为主,耐喷淋层采用陶瓷化硅橡胶带、挤包陶瓷化聚烯烃或无卤阻燃结壳型聚烯烃可提高GB/T 19666—2019中NS耐火试验通过率;不同场景需要结合环境特性、安全等级及标准要求选型。研究表明,合理设计结构、选择材料及遵循相关标准,可保障核电站用耐火电缆在复杂环境中的可靠性,可为其选型与生产提供参考。
To clarify characteristics of fire resistant cables for nuclear power plants and support their selection and manufacturing
an analysis was conducted on their types
safety classifications
quality assurance grades
and structural designs. A comparison was made between different fire resistance test standards (such as GB/T 19666—2019 and BS 6387: 2013)
and structural verification tests were carried out to explore the impact of structures on performance. In terms of classification
fire resistant cables for nuclear power plants mainly include fire resistant low-voltage power cables
control cables
and measurement cables
with safety classifications such as Class 1E and non-Class 1E
and most quality assurance grades being Q2 and Q3. In terms of structure
fire resistant layer is mainly made of mica tape
and the use of ceramic silicone rubber tape
extruded ceramifiable polyolefin
or halogen-free flame retardant crusting polyolefin for the spray-resistant layer could improve the pass rate of NS fire resistance test specified in GB/T 19666—2019. Selection in different scenarios should be based on environmental characteristics
safety levels
and standard requirements. The study showed that reasonable structural design
appropriate material selection
and compliance with relevant standards could ensure the reliability of fire resistant cables for nuclear power plants in complex environments
providing a reference for their selection and manufacturing.
[产业调研网. 2025 年中国耐火型电缆市场现状调查与未来发展前景趋势报告[R]. 2025.
[Industrial research network. Research report on China's fire-resistant cable market: Survey of current status and future development prospects and trends (2025)[R]. 2025.
梁兆荣, 邱懿涛, 杨辉. 耐火电缆试验标准差异分析[J]. 电线电缆, 2025, 68(5): 1-4.
LIANG Z R, QIU Y T, YANG H. Difference analysis of fire-resistant cable test standards[J]. Wire&Cable, 2025, 68(5): 1-4.
[丁运生, 周意杨, 周劲松, 等. 一种耐γ-射线辐照可陶瓷化阻燃耐火电缆护套材料及其制备方法: CN 115785576B[P]. 2024-04-05.
[DING Y S, ZHOU Y Y, ZHOU J S, et al. A γ-ray radiation-resistant, ceramizable, flame-retardant, and fire-resistant cable sheathing material and its preparation method: CN 115785576B[P]. 2024-04-05.
黄万里, 赵迪. 燃烧性能等级A级矿物绝缘柔性耐火电缆优化设计[J]. 电线电缆, 2024, 67(4): 58-61.
HUANG W L, ZHAO D. Optimization design of mineral insulated flexible fire-resistant cables with Level A combustion performance[J]. Wire&Cable, 2024, 67(4): 58-61.
高振军, 张开拓. 一级建筑用难燃耐火电缆的研制及应用[J]. 电线电缆, 2024, 67(1): 31-35.
GAO Z J, ZHANG K T. Development and application of refractory cables for first-class buildings[J]. Wire&Cable, 2024, 67(1): 31-35.