In order to effectively identify potential trouble areas of embankments and prevent major flood disasters before they happen
high-density resistivity method was used to measure a dam in Poyang County where the danger situation was serious.24 anomalies were found
including 11 low resistance anomalies and 13 high resistance anomalies. According to the electrical difference between the dam body and the target body of groundwater infiltration
a preliminary analysis shows that the low resistivity anomaly is caused by the dam body being soaked by flood for a long time
the hidden danger site is prone to water seepage
resulting in high local water content and low resistivity. The high resistance anomaly is due to the plugging of the pipe gushing
cutting off the water flow path
forming a hollow structure similar to the network vein
high resistivity. The high-density resistivity method is used to carry out early warning and key monitoring on the sections that may occur danger
and the effect is obvious in the detection of embankment hidden danger
which is worthy of application and promotion in practice.