刘近. Failure Mechanism and Improvement Measures of Steam-water Pipeline Supports and Hangers for In-service Thermal Power Units[J]. 2020, (4): 135-139. DOI: 10.16056/j.2096-7705.2020.04.027.
there are increasing number of accidents caused by age of steam and water pipe supporter.increases the reliability and safety of power plants operation. Cold and hot state test
performance test and stress check of supporters and hangers and evaluation of the pipe system show that the main reason of Failures of supports and hangers are seriously oil leak of dampers
ultimate pulling pressure position of dampers
the limit failure
the limit self-lock
the blocked expansion of the pipeline and the seriously askew of cross arm and the limit position pulling of the hanger. The operation of the supporters and hangers improved by the following methods
such as replacing the dampers with serious oil leakage
reserving a reasonable scale for the dampers at the limit position
replacing the damaged support hanger and components
repurchasing and installing the unqualified support hanger
reserving a reasonable gap for the failed pipe clamps at the limit position
and adjust the skewed cross arm
etc. The overall stress of piping system is optimized and meets the design and safety requirements. The occurrence of vicious accidents such as pipe cracking and steam leakage has been avoided.
A. Abdennour.An intelligent supervisory system for drum type boilers during severe disturbances[J].International Journal of Electrical Power and Energy Systems,2000(5).
G. Arroyo-Figueroa,E. Solis,A. Villavicencio.SADEP—a fuzzy diagnostic system shell-an application to fossil power plant operation[J].Expert Systems With Applications,1998(1).