刘国弼, 屈红岗, 于鑫. Reason Analysis and Common Problem Discussion on Shutdown of Low Feedwater Flow in Thermal Power Plant[J]. 2019, (4): 44-47. DOI: 10.16056/j.1005-7676.2019.04.011.
火力发电厂给水流量低停机原因分析及共性问题探讨
摘要
通过对350 MW级机组给水流量低停机事件进行分析
提出事故工况下机组给水系统操作及小汽轮机供汽系统切换注意事项
针对发电厂小汽轮机供汽系统提出设计优化方案
并对设计问题及运行方式进行探讨
指出小汽轮机供汽系统在设计时应充分考虑系统暖管及汽源切换过程中系统稳定性等因素
同时应做好事故预想
在操作过程中严格按照相关规程规定执行
为同类型机组提供参考及借鉴。
Abstract
Through the analysis of the shutdown event of low feed water flow for 350 MW units
the matters needing attention in the operation of feed water system and the switchover of steam supply system for boiler feed pump turbine under accident conditions are put forward. The design optimization scheme for the steam supply system of boiler feed pump turbine in power plants is put forward
The design problems and operation modes are discussed
and the steam supply of boiler feed pump turbine is pointed out. In the design of the system
factors such as system stability in the process of switching between heating pipe and steam source should be fully taken into account. At the same time
accident expectation should be made
and relevant regulations should be strictly followed in the operation process.The same type of units can refer for this event.