颜昌盛, 姚文凡. Analysis of Abnormal Power Generation and System Efficiency of a Photovoltaic Distributed Rooftop Power Station[J]. 2018, (4): 36-41. DOI: 10.16056/j.1005-7676.2018.04.010.
the cause of low power generation and low system efficiency(PR value) comparing with its feasibility study report has been thoroughly analyzed. Recently in a power station in Shanxi
the power generation and the PR data is lower than expected after being put into operation after initial operation. As soon as the abnormal situation is realized
a expert team was organized and assigned to site to do further inspection and finally the solution was found successfully.Through the process
the experts found out the main reason that reducing the power generation was the block of the dust
especially the belt shape block of the lower edge of PV component after raining. Therefore
the exclusive cleaning plan to improve the power generation capability was made
as well as the references for the future design and O&M of a similar power station.