某2号机组高中压缸温差大临时处理方案
摘要
某2号机组运行中上下缸温差超过100℃
超出了厂家给出的允许范围
已经影响到机组的正常运行。采取了临时措施
以保证机组安全运行。通过温度偏高测点
加装临时管道
引入高排蒸汽
使上下缸温减小
使机组安全运行。
Abstract
It is more than 100 degrees of HP and MP cylinders in unit No.2
out of the standards
which has a lot of harm. It is a temporary way in order to ensure the safe operation of the unit No.2. It is high-pressure cylinder steam to high temperature points