The structural features and design of a refuse incineration waste heat boiler with a daily processing capacity of 500 tons were introduced. The advantages of superheater
economizer heating surface tubes and other screen modular design were analysed
and the attentions should be noticed during production
transportation and installation. The creative design of increasing the primary air temperature was discussed
and its effects on the economic stability of boiler operation were investigated.