针对传统变压器状态评估方法单一、难以处理多源信息模糊与冲突的问题,文章提出一种基于多源数据融合的智能评估方法。首先,构建涵盖油中溶解气体、绝缘油特性及电气性能的多维度指标体系。其次,采用改进的隶属度函数刻画状态模糊边界,并基于离差平方和最大化模型确定指标最优组合权重,完成各指标群的模糊综合评判。最后,将评判结果作为证据,利用D-S证据理论进行多源融合与决策,输出量化信度的状态评估结论。以1台110 kV变压器实测数据验证,本方法有效识别出设备的早期综合劣化,其“注意”状态的信度经多源融合后由0.401提升至0.503,较传统方法更具前瞻性与可靠性,为变压器状态精准评估提供了新途径。
To address the problems that traditional transformer state assessment methods are relatively simple and have difficulty handling ambiguity and conflicts in multi-source information
this paper proposes an intelligent assessment method based on multi-source data fusion. First
a multidimensional indicator system covering dissolved gas in oil
insulating oil characteristics
and electrical performance is constructed. Second
an improved membership function is used to characterize the fuzzy boundaries of operating states
and the optimal combined weights of the indicators are determined based on a sum of squared deviations maximization model
thereby completing the fuzzy comprehensive assessment of each indicator group. Finally
the assessment results are used as evidence
and D-S evidence theory is employed for multi-source fusion and decision making
outputting state assessment conclusions with quantified confidence degrees. Verification using measured data from a 110 kV transformer shows that the proposed method effectively identifies early comprehensive degradation of the equipment. After multi-source fusion
the confidence degree of the “attention” state increases from 0.401 to 0.503
making the method more forward looking and reliable than traditional methods. This provides a new approach for accurate transformer state assessment.
王刘芳.电力大数据背景下设备状态评估研究现状与展望[J].电网技术,2023,44(5):1637-1647.
郑玉平.基于多源信息融合的电力变压器状态评估指标体系构建[J].电力系统自动化,2021,43(16):165-172.
IEEE Std C57.104-2019.IEEE Guide for the Interpretation of Gases Generated in Mineral Oil-Immersed Transformers[S].2019.
朱德恒,严璋.电气设备状态监测与故障诊断技术[M].北京:中国电力出版社,2009.
陈伟根.基于GA-SVM的变压器油中溶解气体分析与故障诊断[J].电工技术学报,2017,30(8):266-272.
王丰华.基于振动信号与神经网络组合的变压器机械状态识别[J].中国电机工程学报,2019,37(21):6395-6404.
刘云鹏.基于随机森林和DGA的变压器故障诊断方法[J].高电压技术,2018,42(3):925-932.
李 化.电力变压器绝缘状态综合评估中多指标信息融合方法[J].电工技术学报,2016,29(10):277-284.
张冠军.基于模糊综合评判的变压器绝缘状态评估[J].西安交通大学学报,2010,42(5):587-591.
汲胜昌.基于AHP和可变模糊集的变压器状态评估[J].高电压技术,2014,38(10):2719-2725.
吴迪,陈超,龚利武,等.高渗透率分布式电源配电台区状态综合评估[J].农村电气化,2022(9):5-8.
洪东彬,徐利豪,杨桥桥.基于多源数据的乡村微电网清洁能源及运行设备监测预警研究[J].农村电气化,2025(4):63-66.
廖瑞金.多源信息融合技术在电力设备状态评估中的应用与发展[J].电工技术学报,2023,35(19):3997-4012.