1. 延长油田股份有限公司杏子川采油厂,陕西 延安 717400华北电力大学环境科学与工程学院,北京,102206
2. 华北电力大学环境科学与工程学院,北京 102206中国石化石油勘探开发研究院,北京,102206
3. 中国石化石油勘探开发研究院,北京 102206上海交通大学环境科学与工程学院,上海,201306
4. 上海交通大学环境科学与工程学院,上海 201306上海交通大学碳中和发展研究院,上海,201306
5. 上海交通大学碳中和发展研究院,上海,201306
[ "张志升(1974—),男,硕士,正高级工程师,从事油田勘探开发研究。地址:陕西省延安市安塞区杏子川采油厂,邮政编码:717400。E-mail: 464542108@qq.com" ]
[ "林千果(1971—),男,博士,教授,从事碳捕集、利用与封存以及碳监测研究。地址:上海市徐汇区华山路1954号上海交通大学徐汇校区慧谷科技楼,邮政编码:201306。E-mail: qianguo.lin@sjtu.edu.cn" ]
纸质出版:2024
移动端阅览
张志升, 吴向阳, 吴倩, 等. CO2驱油封存泄漏风险管理系统及应用研究[J]. 油气藏评价与开发, 2024,14(1):91-101.
ZHANG Zhisheng, WU Xiangyang, WU Qian, et al. Risk management system and application of CO2 flooding and sequestration leakage[J]. Petroleum Reservoir Evaluation and Development, 2024, 14(1): 91-101.
张志升, 吴向阳, 吴倩, 等. CO2驱油封存泄漏风险管理系统及应用研究[J]. 油气藏评价与开发, 2024,14(1):91-101. DOI: 10.13809/j.cnki.cn32-1825/te.2024.01.013.
ZHANG Zhisheng, WU Xiangyang, WU Qian, et al. Risk management system and application of CO2 flooding and sequestration leakage[J]. Petroleum Reservoir Evaluation and Development, 2024, 14(1): 91-101. DOI: 10.13809/j.cnki.cn32-1825/te.2024.01.013.
CO
2
驱油封存技术在提高原油采收率的同时能实现大规模CO
2
封存。然而,驱油封存过程伴随着多种CO
2
泄漏风险。针对以往CO
2
泄漏风险管理系统的缺乏,特别是缺少基于在线监测的管理系统,难以支撑动态的风险管理,研究基于CO
2
驱油封存泄漏风险管理体系的构建,开发了集成多环境实时风险识别和评估、多空间风险预测、多层级风险预警和全过程风险控制的动态CO
2
泄漏风险管理系统,并应用于鄂尔多斯盆地延长石油CO
2
驱油封存示范项目。案例应用研究表明,所开发的CO
2
泄漏风险管理系统可以全空间动态识别CO
2
驱油封存过程的各种泄漏风险,有效支撑泄漏风险的动态管理,为CO
2
驱油封存项目提供全面及时的安全保障。
CO
2
flooding and sequestration technology can significantly improve crude oil recovery rates while enge. However
the oil displaceabling large-scale CO
2
flooding and sequestration process is accompanied by various CO
2
leakage risks. In response to the lack of previous CO
2
leakage risk management systems
especially the absence of systems based on online monitoring that support dynamic risk management
research has been conducted on the construction of a CO
2
flooding and sequestration leakage risk management system. Based on the construction of CO
2
flooding and storage leakage risk management syst
em
a dynamic CO
2
leakage risk management system integrating multi-environment real-time risk identification and assessment
multi-space risk prediction
multi-level risk early warning and whole process risk control was developed and applied to the CO
2
flooding and storage demonstration project of Yanchang Petroleum in Ordos Basin. Case studies demonstrate that the developed CO
2
leakage risk management system can dynamically identify various leakage risks throughout the CO
2
flooding and sequestration process across all spaces
effectively supporting the dynamic management of leakage risks. This provides comprehensive and timely safety assurance for CO
2
flooding and sequestration projects
ensuring that potential risks are managed and mitigated effectively to maintain the integrity and success of these projects.
0
浏览量
0
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621