闪电释放的大电流及其辐射电磁脉冲是电力及通信设备故障甚至损坏的重要原因。线缆在雷电冲击中的耦合效应受其敷设高度、路径形态及与雷击点相对位置等多种因素影响,进而直接关系到系统的抗扰性能。因此,深入理解不同布设形式下埋地线缆的雷击瞬态响应规律具有重要意义。在广东雷州半岛的野外雷电试验基地搭建了钢结构试验平台,采用人工触发闪电技术,将雷电引至试验平台上方的引雷塔(直接雷击)及邻近变电站(邻近雷击)等不同位置,同步观测了分别布设于平台下方地面与平台表面的22 m长双屏蔽层六芯通信线缆的瞬态电压响应,以及闪电通道光辐射强度、雷电流、辐射电磁场等。分析结果表明,直接雷击情况下,在闪电回击阶段2类线缆电压均呈负极性主导的双极性波形,地面线缆电压峰值更高(0.77~1.09 kV)、上升时间更短(0.82~0.98 μs),平台线缆电压衰减更慢。邻近雷击情况下,因雷电流散流方向改变,2种线缆电压波形均发生极性逆转,峰值显著降低,且地面线缆同样电压峰值更高。相关性分析结果表明,线缆电压峰值与通道磁场及光辐射强度峰值均呈亚线性关系,线缆电压峰值与通道电流峰值、电流变化率峰值间均呈超线性关系。对于2种雷击位置,地电位抬升引起的电势差在线缆雷电瞬态响应中起主导作用,不同雷击位置主要通过改变散流路径来影响线缆电压的极性与强度。本研究为评估通信线缆在真实自然雷电环境中的瞬态响应提供了实验依据。
Lightning-generated high currents and radiated electromagnetic pulses are major causes of communication cable malfunctions. The lightning coupling effects of cables are influenced by multiple factors
including the installation height
the routing configuration
and the relative position to the lightning strike point
which directly determine the interference immunity of system. Therefore
it is of great significance to understand the transient response of cables to lightning under different conditions. A steel platform with communication cables was built at the experiment site on Leizhou Peninsula
Guangdong Province
China. By using rocket-triggered lightning
strikes were triggered to various locations
including a launch tower above the platform (direct strike) and a nearby substation (close-up strike). Synchronous measurements captured transient responses of two 22-meter double-shielded six-core communication cables (one on the ground
the other on the platform) under different deployment and strike conditions
along with lightning channel luminosity
lighting current and radiated electromagnetic field signals. Results show that direct strikes induce bipolar voltage waveforms in both cables
dominated by negative peaks during the return-stroke stage. The ground cable exhibits higher peaks (0.77~1.09 kV) and shorter rise times (0.82~0.98 μs)
while the platform cable shows slower attenuation. For the close-up strike
changes in lightning current dispersion reverse cable voltage polarity with reduced peaks
with the ground cable still having higher peaks. Correlation analysis reveals that
during return-stroke stages
cable voltage peaks have a sublinear relationship with magnetic field and luminosity peaks
and a superlinear relationship with lightning channel current peaks and current change rate peaks. For both direct and close-up strikes
the potential difference caused by ground potential rise dominates cable transient responses. Different strike locations affect the cable voltage polarity and intensity primarily by altering current dispersion paths. These findings provide experimental references for evaluating the transient response of communication cables under actual lightning environments.