1. 电工材料电气绝缘全国重点实验室(西安交通大学),西安,710049
2. 西安交通大学国家储能技术产教融合创新平台(中心),西安,710049
收稿:2026-06-30,
纸质出版:2026
移动端阅览
周飞帆, 孟锦豪, 邹子涵, 等. 基于液冷与相变材料的电池储能系统复合热管理[J]. 高电压技术, 2026,52(6):2865-2875.
ZHOU Feifan, MENG Jinhao, ZOU Zihan, et al. 基于液冷与相变材料的电池储能系统复合热管理[J]. 2026, 52(6): 2865-2875.
周飞帆, 孟锦豪, 邹子涵, 等. 基于液冷与相变材料的电池储能系统复合热管理[J]. 高电压技术, 2026,52(6):2865-2875. DOI: 10.13336/j.1003-6520.hve.20250996.
ZHOU Feifan, MENG Jinhao, ZOU Zihan, et al. 基于液冷与相变材料的电池储能系统复合热管理[J]. 2026, 52(6): 2865-2875. DOI: 10.13336/j.1003-6520.hve.20250996.
高效管理大容量磷酸铁锂电池在合理温度区间并保持电池间的温度一致性,是实现电化学储能系统安全稳定运行的重要前提。为提升大容量电池储能系统的热管理能力,提出了一种基于液冷结合相变材料的复合热管理系统。首先,以280 Ah磷酸铁锂电池为研究对象,考虑电池尺寸、汇流排产热等建立三维电池电热耦合模型,将模型扩展至52块电池单体串联模组并获取其温度分布特性;之后,在模组底部添加液冷板,通过改变冷却液流速,对比不同模组内电池的平均温度、最大温差及流道出入口压差等情况,综合能耗和效果选取合适的流速;最后,在液冷基础上,添加相变材料填充模组内电池间隙,实现液冷结合相变材料的复合热管理。结果表明,采用复合热管理放电期间最大温差在1.5 ℃以内、最高平均温度为51.93 ℃,相比单一液冷热管理最大温差和最高平均温度分别进一步降低了1.1 ℃、3.01 ℃,证明了复合热管理系统的有效性。
Efficient management of large-capacity lithium iron phosphate batteries within a reasonable temperature range and maintenance of temperature consistency among batteries are a crucial prerequisite for the safe and stable operation of electrochemical energy storage systems. To enhance the thermal management capability of large-capacity battery energy storage systems
a composite thermal management system based on liquid cooling combined with phase change materials is proposed. Firstly
taking a 280 Ah lithium iron phosphate battery as the research object
we established a three-dimensional battery electro-thermal coupling model by considering battery size
heat generation from busbar
etc. The model is then extended to a module system with 52 battery cells connected in series to obtain its temperature distribution characteristics. Subsequently
a liquid cooling plate is added at the bottom of the module
and by changing the flow rate of the cooling liquid
the average temperature
maximum temperature difference
and pressure difference at the inlet and outlet of the flow channel of different batteries within the module are compared. The appropriate flow rate is selected based on a comprehensive consideration of energy consumption and effect. Finally
on the basis of liquid cooling
phase change materials are added to fill the gaps between batteries within the module to achieve a composite thermal management method by combining liquid cooling and phase change materials. The results show that
during discharge
the maximum temperature difference is within 1.5 ℃ and the highest average temperature is 51.93 ℃ when using the composite thermal management method. Compared with the single liquid cooling thermal management
the maximum temperature difference and the highest average temperature are further reduced by 1.1 ℃ and 3.01 ℃
respectively
proving the effectiveness of the composite thermal management system.