The contact surface condition directly affects the breaking performance and operational reliability of vacuum circuit breakers. Since vacuum interrupters are typically sealed within solid insulating materials
existing contact assessment methods mostly rely on disassembly procedures
making it difficult to achieve non-destructive measurement on-site in engineering. To address this issue
this paper proposes a non-destructive measurement method based on field emission current during the closing process under DC voltage
enabling quantitative evaluation of contact surface microtopography without disassembling the vacuum interrupter. First
this paper systematically analyzes thermionic-field emission theory
establishes mathematical models suitable for different measurement scenarios
and compares the applicability and measurement accuracy of two methods
namely
AC static contact gap and DC dynamic contact gap measurements. Subsequently
by integrating Fowler-Nordheim and Murphy-Good theories
characteristic field emission current profiles are constructed
and corresponding extraction methods for the field enhancement factor and effective emission area of contacts are proposed. In capacitive switching experiments
the proposed measurement system is integrated with a comprehensive test platform. By sequentially applying high-frequency inrush currents and monitoring field emission characteristics
quantitative tracking of contact surface erosion is achieved. The experimental results demonstrate that this method not only simplifies the measurement process and significantly improves engineering applicability
but also exhibits strong data consistency and theoretical interpretability. The method can provide effective support for online condition assessment and lifespan prediction of vacuum circuit breakers.