特高压直流套管(换流变压器阀侧套管和直流穿墙套管)作为换流变压器与阀厅、直流场连接的关键部件,承担着引线对地绝缘和机械支撑作用,极端复杂的运行工况使直流套管长期承受电、热和机械过应力,其内部电、热、力多物理场相互耦合下极易导致套管内部异常发热及电接触系统劣化甚至过早失效,给换流变压器以及换流站阀厅的安全可靠运行带来极大挑战。该文阐述特高压直流套管电热耦合特性、温度场计算、结构优化设计以及电接触失效机理等方面的最新研究进展。首先,针对现阶段广泛使用的直流套管类型,概述了直流套管的结构特点及关键技术,提取了复杂运行工况下直流套管的电热应力特征,分析了近年来直流套管的典型故障及电-热-力耦合特性。然后从直流套管的电热特性、电场及温度场计算、绝缘结构优化设计、以及电接触系统失效机理等方面系统梳理了国内外相关文献,明确电-热-力多物理场耦合下电接触系统过热劣化及油纸/环氧浸纸绝缘材料过早失效是导致其频繁发生故障的主要原因。最后,对今后特高压直流套管电热特性及电接触系统的研究方向进行了展望,指出电-热-力多物理场耦合作用下电接触部件的微观劣化规律及其失效机制是未来研究的重点方向。
The ultra-high-voltage direct-current (UHVDC) bushings (i.e.
the valve-side bushing of the converter transformer and the DC wall bushing) are critical components connecting the converter transformer to the valve hall and the DC yard. They serve both as insulation between the lead and ground and as mechanical support. Due to the extremely complex operating conditions
DC bushings are subjected to prolonged electrical
thermal
and mechanical overstress. The coupling of electrical
thermal
and mechanical fields within the bushing can easily lead to the degradation or even premature failure of the internal electrical contact system and solid insulation. Such issues pose significant challenges to the safe and reliable operation of converter transformers and valve halls. This paper reviews recent research progress in the electro-thermal characteristics
temperature field analysis
structural optimization
and electrical contact failure mechanisms of UHVDC bushings. First
the structural features and key technologies of widely used bushing types are introduced. The characteristics of electro-thermal stresses under complex operating conditions are identified
and typical failure modes and coupled electro-thermal-mechanical behaviors are analyzed. Then
a comprehensive review is conducted
covering electro-thermal characteristics
insulation structure optimization
and failure mechanisms of electrical contact systems. It is demonstrated that the coupled electro-thermal-mechanical stresses are the primary cause of overheating
degradation of contact components
and premature failure of epoxy-impregnated paper insulation. Finally
future research directions are proposed
highlighting the need for in-depth investigation into the micro-level degradation and failure mechanisms of contact components under multi-physics coupling conditions.