随着新能源电力规模化利用和长距离输送的需求迅速增长,高压直流((high voltage direct current,HVDC)电缆向更高电压等级、更大传输容量的超高压直流(extra high voltage direct current,EHVDC)电缆方向发展,给电缆绝缘系统的电、热、力学等性能提出了更高的要求。EHVDC电缆系统的开发面临着绝缘工作场强更高、厚绝缘交联副产物脱出更难、电缆热失稳风险更大等方面的挑战。该文从电缆绝缘材料、电缆系统、电缆试验方法等方面系统梳理了需要解决的关键技术难题及其产生原因。首先,分析了交联聚乙烯材料中残留副产物对其绝缘性能的影响,以及电缆绝缘中副产物的径向不均匀分布所导致的电场畸变现象,提出了大厚度交联聚乙烯电缆绝缘副产物的控制方法;而低交联、非交联绝缘材料可以减少副产物生成量、提高电气性能,但其抗热变形能力弱,因此要通过高温机械性能试验的考核来保证其电气性能与机械性能的平衡。然后,在电缆绝缘系统层面,分析了电缆绝缘挤出工艺中焦烧现象的危害以及研究现状,强调电缆绝缘长时挤出抗焦烧性能的重要性;针对电缆接头,阐明了绝缘界面处电气性能的下降原因,指出应关注多层绝缘匹配及界面电荷效应。最后,在试验方法方面,论述了EHVDC电缆中热稳定性下降、预鉴定试验周期过长、新型过电压冲击等问题,说明了引入热稳定性试验、扩展鉴定试验、特殊暂态过电压试验的必要性。该研究为后续开发高耐电强度、高温度稳定性、高机械承载力的超高压直流电缆提供了借鉴。
Abstract
With the rapid growth in the demand for large-scale utilization and long-distance transmission of new energy power
high-voltage direct-current (HVDC) cables are developing towards extra-high-voltage direct-current (EHVDC) cables with higher voltage levels and larger transmission capacities. This trend imposes higher requirements on the electrical
thermal
and mechanical properties of cable insulation systems. The development of EHVDC cable system is facing challenges such as higher insulation field strength
more difficult removal of crosslinking byproducts
and higher risk of thermal instability. This article systematically sorts out the key technical challenges that need to be solved and their causes from aspects such as insulation materials
cable insulation systems
and cable test methods. Firstly
the influences of residual byproducts in crosslinked polyethylene (XLPE) on its insulation property and the electric field distortion caused by the radial uneven distribution of byproducts in cable insulation are analyzed
and the control method of byproducts in thick XLPE cable insulation is proposed. Low-crosslinking and non-crosslinked insulation materials can reduce byproduct generation and improve electrical properties
but their thermal deformation resistance is weak. Therefore
the balance between electrical and mechanical properties should be ensured through the examination of high temperature mechanical property tests. Then
at the level of cable insulation system
the hazards and research status of scorch during extrusion are analyzed
emphasizing the importance of the anti-scorch property in the long-term extrusion of cable insulation. For cable joints
the reasons for the decline of electrical property at the insulation interface are clarified
and it is pointed out that attention should be paid to the matching of multi-layer insulation and the interface charge effect. Finally
in terms of the test methods
the problems of thermal stability decline
long prequalification test cycle and new overvoltage impulse in EHVDC cable are discussed. The necessity of introducing thermal stability tests
extended qualification tests
and special temporary overvoltage tests is explained. This research can provide valuable insights for the future development of EHVDC cables with high electrical strength