目前,风机叶片时常遭受雷击而损坏,导致严重的经济损失;但针对叶片接闪特性的试验研究较为缺乏且不全面。为此,在雪峰山野外站搭建了缩比风机叶片雷击放电试验平台,考虑雷电的极性与位置,模拟试验研究了静止和自然旋转叶片的接闪特性,分析了雷击概率及失效机制。结果表明:风机叶片的正负极性雷击接闪特性具有极性效应,接闪点及其雷击概率在负极性时较为集中,而在正极性时较为分散。负极性雷击时,叶片接闪系统的拦截性能较好,尤其是接闪器1(但附近会出现烧蚀损伤)。正极性雷击时,接闪器1的雷击概率明显下降并向其余接闪点转移,使得其他接闪器非常重要;叶身的整体雷击风险约为10%,并且旋转叶片的叶身遭受迎风面的雷击风险高达25%,故必须重视正极性雷击防护。与静止相比,叶片旋转会导致潜在接闪点的雷击概率值发生变化。避雷针可以很好拦截来自背风面的雷电以保护机舱。具有绝缘性的玻璃纤维增强复合材料叶片对内部引下线的电场屏蔽作用有限是导致接闪器拦截失败的原因,建议叶片外覆导体屏蔽引下线电场以优化接闪系统的防护性能。该文模拟试验结果可为风机叶片接闪系统的优化设计提供指导。
At present
wind turbine blades are often damaged by lightning strikes
resulting in serious economic losses; however
experimental studies on the lightning attachment characteristics of the blades are relatively lacking and incomplete. In this paper
a lightning discharge experimental platform for scaled-down wind turbine blades was set up at Xuefeng Mountain field station;moreover
the polarity and location of lightning were taken into consideration
and the lightning attachment characteristics of static and naturally rotating blades were simulated experimentally investigated and the probability of lightning strikes and the failure mechanism were analyzed. The results show that the positive and negative lightning strike attachment characteristics of wind turbine blades have a polarity effect
and the attachment point and its lightning strike probability are more centralized in the negative polarity
while more scattered in the positive polarity. In negative lightning strike
the overall interception performance of the blade lightning protection system (LPS) is better
especially receptor 1 (but ablation damage occurs in the vicinity). Under positive lightning strike
the lightning strike probability of receptor 1 is significantly reduced and transferred to the rest of the attachment point
enabling the other receptor to be very important; however
the overall lightning strike risk to the blade body is about 10%
and the risk of lightning strikes on the windward side of the rotating blade body is up to 25%
so it is necessary to pay attention to the protection of the positive lightning. Compared with stationary
blade rotation will lead to changes in the probability value of lightning strike at potential attachment points. Lightning rods are good at intercepting lightning from the leeward side to protect the nacelle. The limited shielding effect of glassfibre reinforced plastics blades with insulating properties on the electric field of the internal lead wires is the reason for the failure of receptor interception
and it is recommended that the outer conductor of the blades shield the lead wires from the electric field to optimize the protection performance of the LPS. The simulation results of this paper can provide guidance for the optimized design of wind turbine blade LPS.