YANG Ziyue, XIA Chenyang, SUN Anran, et al. Integrated Detection Technology of Position and Foreign Object for Electric Vehicle Wireless Power Transfer[J]. 2026, 46(11): 4723-4734.
YANG Ziyue, XIA Chenyang, SUN Anran, et al. Integrated Detection Technology of Position and Foreign Object for Electric Vehicle Wireless Power Transfer[J]. 2026, 46(11): 4723-4734.DOI: 10.13334/j.0258-8013.pcsee.251542.
对位检测(position detection,PD)和异物检测(foreign object detection,FOD)功能是保证电动汽车无线充电系统(electric vehicle wireless power transfer,EV-WPT)高效安全工作的关键。然而,大多研究仅关注单一功能,未考虑多功能集成后增加结构与逻辑复杂度。为此,文中基于检测线圈阵列时分复用的思想,提出一种用于EV-WPT系统的PD与FOD一体化系统。PD功能中,信标线圈安装在EV-WPT系统副边,激活后产生高频磁场,原边检测线圈阵列感应高频电压;幂次增强加权质心定位算法根据检测线圈采样电压,计算原副边设备的相对位置;FOD功能中,正交解调电路分离检测线圈的同向与正交直流电压分量,并计算检测线圈电压幅值A2和相位差余切cotφ 的变化;金属异物导致A2降低且cotφ 升高,生物导致A2和cotφ 同时降低;最终,所提PD与FOD一体化系统的实验效果良好:在502 mm × 382 mm区域内的平均对位检测误差在10 mm内;40 mm × 40 mm铁片和手使A2分别降低51.8%和59.7%,cotφ 分别升高25.4%和降低39.3%,能够准确检测与识别异物。
Abstract
Position detection (PD) and foreign object detection (FOD) functions are the key to ensuring the efficient and safe operation of electric vehicle wireless power transfer (EV-WPT). However
most of the researches focus solely on a single function without considering the increased structural and logical complexity after multi-function integration. To this end
this paper proposes a position and foreign object integrated detection system for EV-WPT system based on the time-division multiplexing of the detection coil array. In PD function
a beacon coil is installed on the secondary side of the EV-WPT system
which generates an AC magnetic field
and induces high-frequency voltages on the detection coil array. A power-enhanced weighted center-of-mass positioning algorithm calculates the relative positions between the primary coil and secondary coil based on the sampled voltages from detection coils. In FOD function
a quadrature demodulation circuit separates the isotropic and quadrature DC voltage components of the detection coil and calculates the changes in the detection coil voltage amplitude A2 and the phase cotangent cotφ. A metal object (MO) causes a decrease in A2 and an increase in cotφ
while a live object (LO) causes a decrease in both A2 and cotφ. Eventually
the experimental results of the proposed system are effective: the average error of the PD function is within 10 mm in the area of 502 mm × 382 mm; the 40 mm × 40 mm iron sheet and the hand reduce the A2 by 51.8% and 59.7%
and the cotφ increases by 25.4% and decreases by 39.3%