三芯电缆宽频序阻抗的快速精准计算对电缆系统设计及其电磁暂态分析至关重要。传统计算模型忽略邻近效应,电磁暂态程序(electromagnetic transients program,EMTP)模型专注于单频分析,有限元模型在宽频工况下计算效率欠佳。该文针对三芯电缆建立一种考虑邻近效应的序阻抗快速计算方法,通过引入表面导纳算子分解导体电流密度,同时,引入电场积分方程得到导体阻抗;利用矩量法将多个点的电流密度和导体阻抗进行联立,得到仅与导体本身参数有关的阻抗矩阵,称为表面导纳算子-电场积分方程-矩量法(surface operator-enhanced electric field integral equation method of moments,SO-EI-MoM)。利用所提模型求解宽频带工况下两平行导体单位阻抗,并与其他方法对比,验证SO-EI-MoM模型在计算效率与精度方面的优势。进一步地,以YJV22- 220 kV-3×500 mm²电缆作为实例,结果表明,SO-EI-MoM模型计算效率比有限元提高88倍,比EMTP提高2倍;50 Hz下其计算结果与测量值间平均误差为2.89%,优于EMTP结果。最后,基于该模型对不同温度下三芯电缆宽频序阻抗进行计算,并与有限元仿真对比,进一步证实普适性。研究结果可为三芯电缆设计、电磁暂态分析及不同工况下的阻抗特性研究提供一定参考。
In the field of cable system design and electromagnetic transient analysis
the rapid and accurate calculation of the wideband sequence impedance of three-core cables is of vital importance. However
the traditional calculation model generates errors due to the failure to consider the proximity effect. The electromagnetic transients program (EMTP) model focuses on single-frequency analysis
and the finite element model has poor calculation efficiency under wideband conditions. Therefore
in this paper
a fast calculation method of sequence impedance considering the proximity effect is established for three-core cables
and the current density of the conductor is decomposed by introducing the surface admittance operator. Meanwhile
the electric field integral equation is introduced to obtain the impedance of the conductor. The current density at multiple points and the impedance of the conductor are combined by using the method of moments
and the impedance matrix related only to the parameters of the conductor itself is obtained. This method can be called surface operator-enhanced electric field integral equation method of moments (SO-EI-MoM). On this basis
the unit impedances of two parallel conductors under wideband conditions are solved through the traditional analytical model
EMTP model
finite element model and SO-EI-MoM model
and their performances are compared to verify the significant advantages of the SO-EI-MoM model in terms of computational efficiency and accuracy. Furthermore
taking the YJV22-220 kV-3×500 mm² three-core cable as the empirical object
it is found that its computational efficiency is 88 times higher than that of the finite element method and 2 times higher than that of EMTP. At 50Hz
the average error between its calculation result and the actual value is 2.89%
which is better than the result of EMTP. Finally
based on this model
the variation law of the wideband sequence impedance of the three-core cable at different temperatures is analyzed and compared with the finite element simulation
further confirming its universality.