LIU Qingrui, XU Jing, MA Suxia, et al. Calculation of Thermal Stress and Creep Life Analysis of Water-cooled Wall in 350 MW Supercritical Circulating Fluidized Bed Boiler[J]. 2026, 46(8): 3334-3345.
LIU Qingrui, XU Jing, MA Suxia, et al. Calculation of Thermal Stress and Creep Life Analysis of Water-cooled Wall in 350 MW Supercritical Circulating Fluidized Bed Boiler[J]. 2026, 46(8): 3334-3345.DOI: 10.13334/j.0258-8013.pcsee.242966.
Low-load and even ultra-low-load peaking operation has been the operating trend of supercritical circulating fluidized bed boilers. The water-cooled wall thermal deviation
heat transfer deterioration and other problems accompanying the operation under low load conditions aggravate the super-temperature creep damage of the tube wall
which affects its operation life. This paper takes an in-service supercritical circulating fluidized bed boiler as the research object
combines the actual operation data
constructs the simulation model of its temperature field and stress field
explores the distribution law of the temperature
deformation and thermal stress of the tube wall under the low load condition
normal heat transfer
heat transfer deterioration
and different thermal deviation
and evaluates the creep life of the water-cooled wall tubes under different temperatures and stress levels. The results show that when heat transfer deterioration occurs
the maximum temperature of the water-cooled wall tube shifts to the midpoint of the tube wall on the fireward side
and the maximum thermal stress still occurs at the contact point between the tube wall and the fins on the backward side; when the temperature deviation is more than 50℃
the maximum temperature
the maximum deformation
and the maximum thermal stress of the reference tube increase abruptly; and when the heat transfer deterioration occurs
the wall temperature of the tube wall at the danger point reaches 535℃
and the thermal stress reaches 258 MPa
which is close to the life limit of the water-cooled wall tube
so strict temperature control of the water-cooled wall should be prioritized. The results of the study provide a certain reference for the safe operation of supercritical circulating fluidized bed boilers at low load.