基于300MW一次再热分流再压缩超临界二氧化碳(S-CO
2
)布雷顿循环
优化锅炉受热面布置方式
为解决工质压降大和炉膛管壁温度高问题
对S-CO
2
锅炉炉膛进行结构设计优化
提出S-CO
2
锅炉炉膛可采用单炉膛双切圆、垂直管屏的结构布置方式。建立系统性能分析模型并计算了膛侧工质压降和管壁温度并与原始方案进行了比较。结果表明:设计负荷下
优化方案过热气冷壁压降和再热气冷壁压降明显降低。优化后因工质压力损失的减小
从而使系统的发电效率上升、发电标准煤耗降低
在设计负荷下
系统标准发电煤耗减少2.8g/(kW×h)。沿炉膛高度方向
优化方案气冷壁的管外壁最高温度显著低于原始方案
优化方案有更宽的安全裕度
从而保证机组的安全运行。
On the base of 300 MW split-flow recompression and single reheat supercritical CO
2
(S-CO
2
) Brayton cycle
the layout of boiler heating surface optimized. In order to solve the problems of large pressure drop of working fluid and high temperature of furnace tube wall
the furnace structure of S-CO
2
boiler was optimized. In the optimization scheme
furnace of S-CO
2
boiler adopts the single furnace double-tangential circle and the vertical tube structure. The system performance analysis model was built
and both the working fluid pressure drop of furnace side and the temperature of tube wall were calculated and compared with those of the original scheme. The results show that under the design load
the pressure drops of both the superheated cooling wall and the reheated cooling wall in
the optimization scheme are obviously reduced. After optimization
due to the decrease of working fluid pressure loss
the power generation efficiency increases and the standard coal consumption of power generation decreases. Under the design load
the system standard coal consumption of power generation is reduced by 2.8 g/(kW×h). Along the furnace height direction
the maximum temperature of the tube outer wall in the optimization scheme is obviously lower than that of the original scheme
which shows that the optimization scheme has a wider safety margin
so as to ensure the safe operation of the unit.
樊泉桂, 主编.锅炉原理[M].中国电力出版社,2008.
杨世铭著.传热学基础[M].高等教育出版社,1991.
Jing Zhou,Chenhao Zhang,Sheng Su,Yi Wang,Song Hu,Liang Liu,Peng Ling,Wenqi Zhong,Jun Xiang.Exergy analysis of a 1000 MW single reheat supercritical CO 2 Brayton cycle coal-fired power plant[J].Energy Conversion and Management,2018.
Enhui Sun,Jinliang Xu,Mingjia Li,Guanglin Liu,Bingguo Zhu.Connected-top-bottom-cycle to cascade utilize flue gas heat for supercritical carbon dioxide coal fired power plant[J].Energy Conversion and Management,2018.
Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China.Key issues and solution strategies for supercritical carbon dioxide coal fired power plant[J].Energy,2018.
Wengang Bai,Yifan Zhang,Yu Yang,Hongzhi Li,Mingyu Yao.300 MW boiler design study for coal-fired supercritical CO 2 Brayton cycle[J].Applied Thermal Engineering,2018.
Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea.Thermodynamic and economic investigation of coal-fired power plant combined with various supercritical CO 2 Brayton power cycle[J].Applied Thermal Engineering,2018.
Dia Milani,Minh Tri Luu,Robbie McNaughton,Ali Abbas.Optimizing an advanced hybrid of solar-assisted supercritical CO2 Brayton cycle: A vital transition for low-carbon power generation industry[J].Energy Conversion and Management,2017.
Mounir Mecheri,Yann Le Moullec.Supercritical CO 2 Brayton cycles for coal-fired power plants[J].Energy,2016.
Yann Le Moullec.Conceptual study of a high efficiency coal-fired power plant with CO 2 capture using a supercritical CO 2 Brayton cycle[J].Energy,2013.
胡涵,孙恩慧,刘超,李航宁,徐进良,刘欢.超临界二氧化碳分流模式锅炉冷却壁的概念设计[J].中国电机工程学报,2019(22).
李平姣,钟文琪,陈晓乐,刘雪娇.600MW S-CO_2循环燃煤流化床锅炉热量分布及锅炉效率[J].中国电机工程学报,2019(07).
张一帆,王安,白文刚,杨玉,李红智,姚明宇,王月明.300MW超临界二氧化碳锅炉气动力特性及壁温分布[J].中国电机工程学报,2019(06).
吴闯,王顺森,王兵兵,李军.超临界二氧化碳布雷顿循环燃煤发电系统仿真研究[J].中国电机工程学报,2018(21).
张一帆,王生鹏,刘文娟,陈渝楠,王月明,李红智.超临界二氧化碳再压缩再热火力发电系统关键参数的研究[J].动力工程学报,2016(10).
赵新宝,鲁金涛,袁勇,党莹樱,谷月峰.超临界二氧化碳布雷顿循环在发电机组中的应用和关键热端部件选材分析[J].中国电机工程学报,2016(01).
段承杰,杨小勇,王捷.超临界二氧化碳布雷顿循环的参数优化[J].原子能科学技术,2011(12).
阎顺林,张斌,刘帅,焦世超.负荷对电站锅炉运行参数影响特性分析及应达值的确定[J].能源工程,2009(06).
沙龙.1000MW超超临界褐煤锅炉燃烧技术研究[D].哈尔滨工业大学,2014(12).