华中科技大学能源与动力工程学院, 湖北省 武汉市 430074
[ "王鼎(1997), 男, 硕士研究生, 研究方向为太阳能吸热器传热特性数值模拟, 741099174@qq.com" ]
[ "陈宇轩(1993), 男, 博士研究生, 研究方向为太阳能吸热器疲劳蠕变分析, cyx0126@hust.edu.cn" ]
[ "肖虎(1995), 男, 硕士研究生, 研究方向为空气吸热器结构优化, 1061094586@qq.com" ]
张燕平(1971), 女, 博士, 副教授, 主要从事太阳能热发电系统设计优化方面的研究, 本文通信作者, zyp2817@hust.edu.cn
收稿:2021-07-30,
纸质出版:2021-12-31
移动端阅览
王鼎, 陈宇轩, 肖虎, 等. 采用不同传热工质的锥形腔式吸热器传热特性对比分析[J]. 发电技术, 2021,42(6):682-689.
Ding WANG, Yuxuan CHEN, Hu XIAO, et al. Comparative Analysis of Heat Transfer Characteristics of Conical Cavity Receivers With Different Heat Transfer Fluids[J]. Power Generation Technology, 2021, 42(6): 682-689.
王鼎, 陈宇轩, 肖虎, 等. 采用不同传热工质的锥形腔式吸热器传热特性对比分析[J]. 发电技术, 2021,42(6):682-689. DOI: 10.12096/j.2096-4528.pgt.21096.
Ding WANG, Yuxuan CHEN, Hu XIAO, et al. Comparative Analysis of Heat Transfer Characteristics of Conical Cavity Receivers With Different Heat Transfer Fluids[J]. Power Generation Technology, 2021, 42(6): 682-689. DOI: 10.12096/j.2096-4528.pgt.21096.
为探究传热工质对太阳能吸热器传热特性的影响,利用光线追踪和计算流体动力学方法,对采用超临界CO
2
和压缩空气作为传热工质的锥形腔体吸热器的传热特性进行对比分析。基于数值模拟讨论了吸热器锥角、工质进口流量和进口温度对吸热器传热性能的影响规律。结果表明:相同工况下,压缩空气的出口温度比超临界CO
2
高,但相应的吸热器热效率和系统光热转化效率却较低。对于2种传热工质,系统光热转化效率均在锥角为4.12°时取得最优值。在研究的运行参数范围内,传热工质的出口温度随进口温度的增加呈线性增长;当流量超过0.04 kg/s时,继续增大流量对提高系统光热转化效率作用较小。
To explore the influence of heat transfer fluids on the heat transfer characteristics of solar receivers
the heat transfer characteristics of conical cavity receivers with supercritical CO
2
and compressed air as heat transfer fluids were compared and analysed by combining ray tracing and computational fluid dynamics method. Based on numerical simulation
the effects of cone angle
fluid inlet mass flow rate and inlet temperature on heat transfer performance of receivers were discussed. The results show that under the same working conditions
the outlet temperature of compressed air is higher than that of supercritical CO
2
but the corresponding receiver thermal efficiency and system photothermal conversion efficiency are lower. For the two heat transfer fluids
the system photothermal conversion efficiencies reach the optimal values with the cone angle of 4.12°. In the range of operating parameters studied
the outlet temperature of heat transfer fluids increase linearly with the increase
of inlet temperature. Once the mass flow rate exceeds 0.04 kg/s
increasing the mass flow rate has little effect on improving the photothermal conversion efficiency of the system.
史洁, 刘晓飞. 新能源功率预测算法优化研究[J]. 发电技术, 2019, 40(1): 78-82.
SHI J, LIU X F. The optimization research approaches for renewable energy output forecasting[J]. Power Generation Technology, 2019, 40(1): 78-82.
童家麟, 吕洪坤, 李汝萍, 等. 国内光热发电现状及应用前景综述[J]. 浙江电力, 2019, 38(12): 25-30.
TONG J L, LYU H K, LI R P, et al. Review on status and application prospect of domestic CSP generation[J]. Zhejiang Electric Power, 2019, 38(12): 25-30.
佟锴, 杨立军, 宋记锋, 等. 聚光太阳能集热场先进技术综述[J]. 发电技术, 2019, 40(5): 413-425.
TONG K, YANG L J, SONG J F, et al. Review on advanced technology of concentrated solar power concentrators[J]. Power Generation Technology, 2019, 40(5): 413-425.
KASAEIAN A, KOURAVAND A, RAD M, et al. Cavity receivers in solar dish collectors: a geometric overview[J]. Renewable Energy, 2020, 169(14): 53-79.
ZOU C Z, ZHANG Y P, FALCOZ Q, et al. Design and optimization of a high-temperature cavity receiver for a solar energy cascade utilization system[J]. Renewable Energy, 2017, 103: 478-489.
TAN Y, ZHAO L, BAO J, et al. Experimental investigation on heat loss of semi-spherical cavity receiver[J]. Energy Conversion and Management, 2014, 87: 576-583.
PAVLOVIC S, LONI R, BELLOS E, et al. Comparative study of spiral and conical cavity receivers for a solar dish collector[J]. Energy Conversion and Management, 2018, 178: 111-122.
DAABO A M, MAHMOUD S, AL-DADAH R K, et al. Numerical investigation of pitch value on thermal performance of solar receiver for solar powered Brayton cycle application[J]. Energy,2017, 119(15): 523-539.
QIU K, YAN L, NI M, et al. Simulation and experimental study of an air tube-cavity solar receiver[J]. Energy Conversion and Management, 2015, 103(10): 847-858.
郭缝伟. 基于MCRT和FVM方法的碟式太阳能聚光集热系统的光热转换特性数值研究[D]. 重庆: 重庆大学, 2019.
GUO F W. Numerical study on the light-to-heat conversion characteristics of the dish-type solar energy concentrating and collecting system based on MCRT and FVM methods[D]. Chongqing: Chongqing University, 2019.
BENOIT H, SPREAFICO L, GAUTHIER D, et al. Review of heat transfer fluids in tube-receivers used in concentrating solar thermal systems: properties and heat transfer coefficients[J]. Renewable and Sustainable Energy Reviews, 2016, 55: 298-315.
LONI R, ASKARI A, SLI-ARDEH E, et al. Numerical comparison of a solar dish concentrator with different cavity receivers and working fluids[J]. Journal of Cleaner Production, 2018, 198: 1013-30.
陶文铨. 数值传热学[M]. 西安: 西安交通大学出版社, 2001: 128-129.
TAO W Q. Numerical heat transfer[M]. Xi'an: Xi'an Jiaotong University Press, 2001: 128-129.
CHU S, BAI F, ZHANG X, et al. Experimental study and thermal analysis of a tubular pressurized air receiver[J]. Renewable Energy, 2018, 125: 413-424.
ZOU C Z, FENG H Y, ZHANG Y P, et al. Geometric optimization model for the solar cavity receiver with helical pipe at different solar radiation[J]. Frontiers in Energy, 2019, 13(2): 1-12.
ZHANG Y P, XIAO H, ZOU C Z, et al. Combined optics and heat transfer numerical model of a solar conical receiver with built-in helical pipe[J]. Energy, 2020, 193: 116775.
ZHANG Y P, Chen Y X, ZOU C Z, et al. Experimental investigation on heat-transfer characteristics of a cylindrical cavity receiver with pressurized air in helical pipe[J]. Renewable Energy, 2021, 163: 320-330.
BELLOS E, BOUSI E, TZIVANIDIS C, et al. Optical and thermal analysis of different cavity receiver designs for solar dish concentrators[J]. Energy Conversion and Management X, 2019, 2: 100013.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621