华电电力科学研究院有限公司, 浙江省 杭州市 310030
[ "何子春(1971), 男, 高级工程师, 从事高低压电气试验、发电厂启动调试和技术监督管理工作" ]
[ "李养俊(1985), 男, 硕士, 工程师, 从事电气试验及技术监督管理工作, elitist21@qq.com" ]
收稿:2018-11-08,
纸质出版:2019-10
移动端阅览
何子春, 李养俊, 张强, 等. 汽轮发电机进相能力分析及试验验证[J]. 发电技术, 2019,40(5):488-492.
Zichun HE, Yangjun LI, Qiang ZHANG, et al. Analysis and Test Verification of Turbine Generator's Leading Phase Operation Capability[J]. Power Generation Technology, 2019, 40(5): 488-492.
何子春, 李养俊, 张强, 等. 汽轮发电机进相能力分析及试验验证[J]. 发电技术, 2019,40(5):488-492. DOI: 10.12096/j.2096-4528.pgt.18233.
Zichun HE, Yangjun LI, Qiang ZHANG, et al. Analysis and Test Verification of Turbine Generator's Leading Phase Operation Capability[J]. Power Generation Technology, 2019, 40(5): 488-492. DOI: 10.12096/j.2096-4528.pgt.18233.
发电机进相运行是发电机在保持正常有功输出的情况下调节励磁,使发电机欠励磁运行,并从系统中吸收无功的一种运行方式,其进相深度一般受发电机静态稳定极限、定子端部构件发热等因素制约。在对发电机进相运行特征、功角变化及进相运行限制因素分析的基础上,以某火电厂600 MW发电机组为例,分析并记录发电机功角、定子电压、厂用电压等电气量及发电机端部温升在进相试验中的实时数据和变化情况,验证了发电机进相运行深度及其限制因素,检验了自动励磁调节器在进相运行中的调节性能及稳定性,为发电机组后续进相运行实践提供数据支撑,提出的改善策略可有效提升机组进相运行能力。
The generator leading phase operation is an operation mode in which the generator adjusts the excitation to make the generator under-excited and maintains reactive power from the system while maintaining the normal active output. The leading phase depth is generally affected by the static stability limit of the generator
the stator end member heating and other factors. Based on the analysis of generator leading phase operation characteristics
power angle change and leading phase operation limit factors
a 600MW generator in a thermal power plant was taken as an example to analyse and record the electrical angle of the generator
stator voltage
factory voltage
the real-time data and changes of the temperature rise of the generator end in the leading phase test. The leading phase running depth of the generator and its limiting factors was verified
and the regulation performance and stability of the automatic excitation regulator in the leading phase operation was tested. It provided data support for the follow-up leading phase operation of the generator set. The proposed improvement strategy can effectively improve the leading phase operation capacity of the generator set.
石立宝, 史中英, 姚良忠, 等.现代电力系统连锁性大停电事故机理研究综述[J].电网技术, 2010, 34(3):48-54.
李贺昌, 沈军.300 MW发电机组并网进相运行实践分析[J].冶金动力, 2013, 156(2):1-2.
李金辉.发电侧涉网保护相关技术研究[D].武汉: 华中科技大学, 2016.
周德贵, 巩北宁.同步发电机运行技术与实践[M].北京:中国电力出版社, 1996.
朱建立.发电机进相运行分析[J].电力安全技术, 2015, 17(2):9-12.
郑惠萍, 侯春青.300 MW机组进相运行分析研究[J].山西电力, 2001, 101(6):1-3.
徐谦, 翁海胜.同步发电机进相运行[J].冶金动力, 2003, 99(5):24-27.
李发海, 朱东起.电机学[M].5版.北京:科学出版社, 2017.
中国电力企业联合会.同步发电机进相试验导则: DL/T 1523-2016[S].北京: 中国电力出版社, 2016.
多俊龙.发电机进相运行条件下的系统暂态稳定性分析[D].郑州: 郑州大学, 2016.
刘华林.发电机进相试验分析与探讨[J].广西电力, 2015, 38(2):43-45.
刘立瑞, 尹项根, 沈明德, 等.发电机组进相运行在电厂的试验与探讨[J].华北电力大学学报, 2003, 30(1):107-109.
鲜霄, 寻志伟, 周道军, 等.大型汽轮发电机运行与无功控制[J].电工技术学报, 2015, 30(5):98-104.
蒋石林.发电机进相试验的几点体会[J].云南电力技术, 2003, 31(2):34-43.
李子峰.厂用电系统继电保护优化[J].热力发电, 2015, 44(9):133-116.
刘谢.大型火电厂厂用电接线优化[J].电工技术, 2019, 38(5):47-50.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621