Bo XU, Hai ZHAO, Qiang GAO. Analysis on the Leakage of Boiler Heating Surface Tube of Thermal Power Plant[J]. Power Generation Technology, 2018, 39(6): 537-541.
Bo XU, Hai ZHAO, Qiang GAO. Analysis on the Leakage of Boiler Heating Surface Tube of Thermal Power Plant[J]. Power Generation Technology, 2018, 39(6): 537-541. DOI: 10.12096/j.2096-4528.pgt.18026.
The high-temperature superheater bursting accident is one of the main factors that affect the safe operation of power plants
and causes the greatest loss. Based on the actual work in the field
the reasons for the leakage of final superheater of boiler No. 1 in a power plant are discussed. Through a variety of test means such as macroscopic test
chemical composition analysis
mechanical properties test and microstructure observation
the tubes are comprehensively analyzed to improve the failure of the heating surface tube of the boiler. The analysis shows that the leakage of the last stage superheater is caused by long overheating. The microstructure near the leakage position is ferrite plus carbides