Gulshan Sharma, K. Narayanan, T. Adefarati, 等. Frequency regularization of a linked wind-diesel system using dual structure fuzzy with ultra-capacitor[J]. 现代电力系统保护与控制(英文), 2022,7(1):1-9.
Gulshan Sharma, K. Narayanan, T. Adefarati, et al. Frequency regularization of a linked wind–diesel system using dual structure fuzzy with ultra-capacitor[J]. Protection and Control of Modern Power Systems, 2022, 7(1): 1-9.
Gulshan Sharma, K. Narayanan, T. Adefarati, 等. Frequency regularization of a linked wind-diesel system using dual structure fuzzy with ultra-capacitor[J]. 现代电力系统保护与控制(英文), 2022,7(1):1-9.DOI: 10.1186/s41601-022-00233-2.
Gulshan Sharma, K. Narayanan, T. Adefarati, et al. Frequency regularization of a linked wind–diesel system using dual structure fuzzy with ultra-capacitor[J]. Protection and Control of Modern Power Systems, 2022, 7(1): 1-9.DOI: 10.1186/s41601-022-00233-2.
Frequency regularization of a linked wind-diesel system using dual structure fuzzy with ultra-capacitor
摘要
Microgrids (µ-grids) are gaining increased interest around the world for supplying cheap and clean energy. In this paper
a µ-grid comprising a wind turbine generator (WTG) and diesel generator (DG) is considered. It is one of most practical and demanding systems suitable for the present energy crisis in isolated or rural areas. However
wind energy is intermittent in nature while load demand changes frequently. Therefore
a µ-grid can experience large frequency and power fluctuations. The speed governor of the DG tries to minimize the frequency and power deviations in µ-grid though its operation is slow and cannot adequately minimize system deviations. The paper proposes a novel arrangement based on a dual structured fuzzy (DSF) whose structure changes according to the switching limit with a reduced rule base. It has the capability to switch between proportional and integral actions and hence improves the frequency regularization of the µ-grid. The proposed strategy is tested in a µ-grid and the results considering step load alteration
load alteration at different instants of time
nonstop changing load request are compared with some of the well published methods to validate the effectiveness and simplicity of the present design. In addition
it shows that ultra-capacitor establishment in a µ-grid has a positive impact in minimizing system deviations with DSF for the studied cases.
Abstract
Microgrids (μ-grids) are gaining increased interest around the world for supplying cheap and clean energy. In this paper
a μ-grid comprising a wind turbine generator (WTG) and diesel generator (DG) is considered. It is one of most practical and demanding systems suitable for the present energy crisis in isolated or rural areas. However
wind energy is intermittent in nature while load demand changes frequently. Therefore
a µ-grid can experience large frequency and power fluctuations. The speed governor of the DG tries to minimize the frequency and power deviations in µ-grid though its operation is slow and cannot adequately minimize system deviations. The paper proposes a novel arrangement based on a dual structured fuzzy (DSF) whose structure changes according to the switching limit with a reduced rule base. It has the capability to switch between proportional and integral actions and hence improves the frequency regularization of the μ-grid. The proposed strategy is tested in a μ-grid and the results considering step load alteration
load alteration at different instants of time
nonstop changing load request are compared with some of the well published methods to validate the effectiveness and simplicity of the present design. In addition
it shows that ultra-capacitor establishment in a μ-grid has a positive impact in minimizing system deviations with DSF for the studied cases.
Preventive Dispatch Against Attack of Adjustable Load on Power System Frequency
Hierarchical under frequency load shedding scheme for inter-connected power systems
Designing of robust frequency stabilization using optimized MPC-(1+PIDN) controller for high order interconnected renewable energy based power systems
A Robust Estimation Method for the Coupling Matrix in Non-Contact Measurement of Switching Transient Voltages in 500 kV Transmission Lines
Distribution Network Optimization Based on Topology Security-Constrained Integrated Reinforcement Learning
相关作者
Yuan Zhang
Mingxu Xiang
Zhengwen Huang
Zhifang Yang
Guowei Cai
Shuyu Zhou
Cheng Liu
Yuchi Zhang
相关机构
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University
Department of Electronic and Electrical Engineering, College of Engineering, Design & Physical Sciences, Brunel University London, Uxbridge
School of Electrical Engineering, Northeast Electrical Power University
Department of Control & Instrumentation Engineering, Interdisciplinary Research Center for Renewable Energy and Power Systems (IRC-REPS), King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia