Mohd Zuhaib, Mohd Rihan, Mohd Tayyab Saeed. A Novel Method for Locating the Source of Sustained Oscillation in Power System using Synchrophasors Data[J]. 现代电力系统保护与控制(英文), 2020,5(4):1-12.
Mohd Zuhaib, Mohd Rihan, Mohd Tayyab Saeed. A novel method for locating the source ofsustained oscillation in power system usingsynchrophasors data[J]. Protection and Control of Modern Power Systems, 2020, 5(4): 1-12.
Mohd Zuhaib, Mohd Rihan, Mohd Tayyab Saeed. A Novel Method for Locating the Source of Sustained Oscillation in Power System using Synchrophasors Data[J]. 现代电力系统保护与控制(英文), 2020,5(4):1-12.DOI: 10.1186/s41601-020-00178-4.
Mohd Zuhaib, Mohd Rihan, Mohd Tayyab Saeed. A novel method for locating the source ofsustained oscillation in power system usingsynchrophasors data[J]. Protection and Control of Modern Power Systems, 2020, 5(4): 1-12.DOI: 10.1186/s41601-020-00178-4.
A Novel Method for Locating the Source of Sustained Oscillation in Power System using Synchrophasors Data
Large interconnected power systems are usually subjected to natural oscillation (NO) and forced oscillation (FO). NO occurs due to system transient response and is characterized by several oscillation modes
while FO occurs due to external perturbations driving generation sources. Compared to NO
FO is considered a more severe threat to the safe and reliable operation of power systems. Therefore
it is important to locate the source of FO so corrective actions can be taken to ensure stable power system operation. In this paper
a novel approach based on two-step signal processing is proposed to characterize FO in terms of its frequency components
duration
nature
and the location of the source. Data recorded by the Phasor Measurement Units (PMUs) in a Wide Area Monitoring System (WAMS) is utilized for analysis. As PMU data usually contains white noise and appears as multi-frequency oscillatory signal
the first step is to de-noise the raw PMU data by decomposing it into a series of intrinsic mode functions (IMF) using Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) technique. The most appropriate IMF containing the vital information is selected using the correlation technique. The second step involves various signal processing and statistical analysis tools such as segmented Power Spectrum Density (PSD)
excess kurtosis
cross PSD etc. to achieve the desired objectives. The analysis performed on the simulated two-area four-machine system
reduced WECC-179 bus 29 machine system
and the real-time power system PMU data set from ISO New England
demonstrates the accuracy of the proposed method. The proposed approach is independent of complex network topologies and their characteristics
and is also robust against measurement noise usually contained in PMU data.
Abstract
Large interconnected power systems are usually subjected to natural oscillation (NO) and forced oscillation (FO). NO occurs due to system transient response and is characterized by several oscillation modes
while FO occurs due to external perturbations driving generation sources. Compared to NO
FO is considered a more severe threat to the safe and reliable operation of power systems. Therefore
it is important to locate the source of FO so corrective actions can be taken to ensure stable power system operation. In this paper
a novel approach based on two-step signal processing is proposed to characterize FO in terms of its frequency components
duration
nature
and the location of the source. Data recorded by the Phasor Measurement Units (PMUs) in a Wide Area Monitoring System (WAMS) is utilized for analysis. As PMU data usually contains white noise and appears as multi-frequency oscillatory signal
the first step is to de-noise the raw PMU data by decomposing it into a series of intrinsic mode functions (IMF) using Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) technique. The most appropriate IMF containing the vital information is selected using the correlation technique. The second step involves various signal processing and statistical analysis tools such as segmented Power Spectrum Density (PSD)
excess kurtosis
cross PSD etc. to achieve the desired objectives. The analysis performed on the simulated two-area four-machine system
reduced WECC-179 bus 29 machine system
and the real-time power system PMU data set from ISO New England
demonstrates the accuracy of the proposed method. The proposed approach is independent of complex network topologies and their characteristics
and is also robust against measurement noise usually contained in PMU data.