尚凤, 陈泓宇, 周凌九, et al. Effect of pressure equalizing tube throttling device on gap flow and head cover air admission[J]. Journal of Hydroelectric Engineering, 2026, 45(9).
尚凤, 陈泓宇, 周凌九, et al. Effect of pressure equalizing tube throttling device on gap flow and head cover air admission[J]. Journal of Hydroelectric Engineering, 2026, 45(9).DOI: 10.11660/slfdxb.20260905.
To improve the behavior of flows in the runner-headcover gap
this paper describes a novel throttling device installed in the pressure equalizing pipe of a pump-turbine unit
focusing on its effects on flow regime and air admission in the gap. We conduct numerical simulations of the runner-head cover gap
using the CFD method
the SST k-ω turbulence model
and the Volume of Fluid (VOF) multiphase flow model. And
in a case study of the Meizhou pumped storage station
throttling orifices with different diameters (relative diameters d/D = 0.238
0.298
0.357
0.476) are examined and compared against the case of no installation. Results show a smaller throttling orifice size induces vortices and backflows in the equalizing pipe. The size has a significant influence on the gap leakage flow rate and the axial force on the lower wall
and a considerable effect on the air admission performance; The flow rate
under the condition of d/D ≥ 0.357
is lowered effectively with little impact on the wall force. At d/D = 0.476
peak values occur in the total gas volume fraction and the fraction in the outer cavity of the gap
indicating the best air admission effect under this orifice condition. For the study case
we recommend the optimal size of d/D = 0.476 based on a comprehensive consideration of the gap flow and air admission performance. Our findings lay a basis for optimizing the structural design of the unit’s equalizing pipe and improving the units safe and stable operation.