王立安, 傅中志, 丁强生, et al. Failure criterion of copper water-stops under three-dimensional deformation[J]. Journal of Hydroelectric Engineering, 2024, 43(5).
王立安, 傅中志, 丁强生, et al. Failure criterion of copper water-stops under three-dimensional deformation[J]. Journal of Hydroelectric Engineering, 2024, 43(5).DOI: 10.11660/slfdxb.20240509.
Copper water-stop is the most important component for preventing water leak through the joints of hydraulic concrete structures. Concrete structures often experience uneven deformation under gravity and hydrostatic pressure
resulting in tension (or compression)
settlement
and shear deformation (relative displacement) between the two wings of a copper water-stop. Its safety depends on the magnitude of the three-dimensional deformation
which is often judged by the displacement in each direction separately
without considering the coupling of different directions. This paper presents an experimental study of shear tests on copper water-stops under different tensile and settlement displacements
using a test stand that allows independent control of three directions and a total of 40 specimens in two different sizes are designed and fabricated. We examine shear deformation
its variations
and the failure modes of the specimens
and obtain a failure envelope surface in the three-dimensional displacement space. A failure criterion is derived for copper water-stops under three-dimensional displacement for judging the safety of similar water-stops.