1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University,Xi'an,China
2. State Key Laboratory of Advanced Power Transmission Technology, China Electric Power Research Institute,Beijing,China
3. ,and
4. Lisheng Zhong
5. State Grid Corporation of China,Beijing,China
6. Zhejiang University,Hangzhou,China
7. Chong Zhang
纸质出版:2025
移动端阅览
Wenpeng Li, Shuxin Bi, Chong Zhang, 等. The Extra-Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross-Linked Polyethylene Cable Insulation Materials[J]. 高电压(英文), 2025,10(6).
Wenpeng Li, Shuxin Bi, Chong Zhang, et al. The Extra-Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross-Linked Polyethylene Cable Insulation Materials[J]. High Voltage, 2025, 10(6).
Wenpeng Li, Shuxin Bi, Chong Zhang, 等. The Extra-Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross-Linked Polyethylene Cable Insulation Materials[J]. 高电压(英文), 2025,10(6). DOI: 10.1049/hve2.70136.
Wenpeng Li, Shuxin Bi, Chong Zhang, et al. The Extra-Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross-Linked Polyethylene Cable Insulation Materials[J]. High Voltage, 2025, 10(6). DOI: 10.1049/hve2.70136.
Cross-linking byproducts in the cross-linked polyethylene (XLPE) cable insulation material significantly affect the insulation properties of XLPE
and the non-destructive detection method for cross-linking byproducts during cable degassing process still faces great challenges. This work develops an extra-low frequency (ELF) dielectric analysis method based on time-dependent polarisation current for non-destructive detection of byproducts in XLPE. The effects of single byproduct of acetophenone and cumyl alcohol on the ELF dielectric properties of XLPE are studied separately. The ELF associated static permittivity and the dielectric loss of XLPE rise as the content of the single byproduct increases
and the α relaxation (10−4–10−3 Hz) and β relaxation (10−3–10−2 Hz) of XLPE are observed. Ionisation of acetophenone occurs above electric field strength of 20 kV
whereas ionisation tends to saturate above 50 kV. The optimal field strength for ELF dielectric testing of XLPE is determined to be 20–50 kV. Furthermore
the degassing factor is proposed to accurately determine the removal of byproducts. Based on these
the non-destructive detection of degassing of XLPE cable is achieved. The proposed ELF dielectric analysis method enables the non-destructive detection of byproducts in cables
opening a new avenue for cable degassing effect evaluation.
Cross-linking byproducts in the cross-linked polyethylene (XLPE) cable insulation material significantly affect the insulation properties of XLPE
and the non-destructive detection method for cross-linking byproducts during cable degassing process still faces great challenges. This work develops an extra-low frequency (ELF) dielectric analysis method based on time-dependent polarisation current for non-destructive detection of byproducts in XLPE. The effects of single byproduct of acetophenone and cumyl alcohol on the ELF dielectric properties of XLPE are studied separately. The ELF associated static permittivity and the dielectric loss of XLPE rise as the content of the single byproduct increases
and the α relaxation (10−4–10−3 Hz) and β relaxation (10−3–10−2 Hz) of XLPE are observed. Ionisation of acetophenone occurs above electric field strength of 20 kV
whereas ionisation tends to saturate above 50 kV. The optimal field strength for ELF dielectric testing of XLPE is determined to be 20–50 kV. Furthermore
the degassing factor is proposed to accurately determine the removal of byproducts. Based on these
the non-destructive detection of degassing of XLPE cable is achieved. The proposed ELF dielectric analysis method enables the non-destructive detection of byproducts in cables
opening a new avenue for cable degassing effect evaluation.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621