Optimizing daylighting performance and energy efficiency through the integration of parametric split louvers in office buildings
The incorporation of split louvers into building systems provides substantial potential for enhancing daylighting performance and
consequently
reducing lighting energy consumption. This study focuses on the critical aspect of determining the optimal positioning of split louver sections to ensure well-distributed daylight in indoor spaces and adding parametric control as a daylight redirection system. This research aims to investigate indoor daylight environments by modifying the relationships and configurations of split louver sections and enhancing the efficiency of daylighting performance through the parametric control of the split louver. In addition
it investigates the energy-saving potentials of using the parametric split louver through the reduction of electric lighting consumption. The study demonstrates that the daylighting performance of the split louver depends upon the status of each section. Specifically
the effects of the upper section of the split louver are predominantly apparent in the rear area of the room
whereas the lower section markedly enhances illumination in the frontal area near windows
particularly during winter months when the lower solar angles. Secondly
the daylighting efficiency of the parametric split louver outperforms that of the conventional single louver in terms of daylight distribution and availability. The efficient daylight performance is evident in the uniform distribution of illuminance within the useful daylight illuminance (UDI) range of 300–500 lux on all typical dates
reaching 44 % and 55 % during the morning and noon
respectively
on March 21st Additionally
the electric lighting efficiency of the parametric split louver surpasses conventional louver throughout the day for all typical dates
resulting in notable lighting energy savings
with average percentages 69.9 % and 63.5 % on March 21st and December 21st
respectively
while June 21st shows lower efficiency with 43.63 % savings. This study contributes valuable insights for architects and designers seeking to create energy-efficient and well-illuminated indoor environments through the integration of parametric split louver.
Enhancing energy efficiency in shipping container house: A novel approach using hybrid louver systems
Enhancing building envelopes: Parametric analysis of shading systems for opaque facades and their comparison with cool paints
Integration opportunities, energy and financial profitability of photovoltaic systems in dry and hot climates
Investigation of Theoretical Models, Pumping-Recharge Well Arrangements and System Performance of Abandoned Mine Water Source Heat Pump
Analysis of indoor set-point temperature of split-type ACs on thermal comfort and energy savings for office buildings in hot-humid climates
相关作者
MaoBin Hu
Peng Hu
Amir Hamza
Farrukh Saleem
Yifang Dong
Muna Alsukkar
Adnan Ibrahim
Ali Ghahramani
相关机构
Department of Thermal Science and Energy Engineering, University of Science and Technology of China
Department of Architectural Engineering, Faculty of Engineering, The Hashemite University, P.O. Box 330127
Institute of Microelectronics, Chinese Academy of Sciences
CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China
School of Engineering Science, University of Science and Technology of China