Pengyu Yan, Fei Yu, Shenyi Cui, 等. Approach on enhancing the air conditioning system to improve the winter thermal environment in Eastern China Region's airport terminals[J]. 能源与人工环境(英文), 2026,7(1):239-252.
Pengyu Yan, Fei Yu, Shenyi Cui, et al. Approach on enhancing the air conditioning system to improve the winter thermal environment in Eastern China Region's airport terminals[J]. Energy and Built Environment, 2026, 7(1): 239-252.
Pengyu Yan, Fei Yu, Shenyi Cui, 等. Approach on enhancing the air conditioning system to improve the winter thermal environment in Eastern China Region's airport terminals[J]. 能源与人工环境(英文), 2026,7(1):239-252. DOI: 10.1016/j.enbenv.2024.10.001.
Pengyu Yan, Fei Yu, Shenyi Cui, et al. Approach on enhancing the air conditioning system to improve the winter thermal environment in Eastern China Region's airport terminals[J]. Energy and Built Environment, 2026, 7(1): 239-252. DOI: 10.1016/j.enbenv.2024.10.001.
Approach on enhancing the air conditioning system to improve the winter thermal environment in Eastern China Region's airport terminals
摘要
Abstract
Passengers typically spend much time in commercial zones of terminals for retail
meals
and other services. Enhancing the study of thermal comfort in this local space is necessary. The climate in the Eastern China Region is variable and complex
making it more challenging to maintain the indoor thermal environment. This study conducted field measurements in winter in a commercial zone of one terminal to assess the thermal environment. Numerical simulations and PMV-PPD analyses were performed using the Computational Fluid Dynamics (CFD) program The results showed that the overall humidity in the commercial zone was low. There were notable differences in the temperatures and velocities of supply air among different air vents on the commercial island. Based on these initial conditions obtained by measurements
the simulations showed that localized areas under the breathing plane are either too hot (24°C and above) or too cold (18°C and below). The dissatisfaction percentage of the population exceeds 27%. This paper proposed that through enhancements in the air vent dimensions
layout
and air supply conditions
the temperature can be maintained in the range of 20-24°C. Furthermore
the PMV could be controlled within the range of -0.5 to 0.5. PPD was below 10%
reflecting compliance with Class I heating standards. Overall
findings from this study provide a less costly modification for thermal comfort improvement in commercial zones
and serve as a reference for the design and operation of air-conditioning systems to ensure thermal comfort in airport terminals’ commercial zones.
Investigation of double-PCM based PV composite wall for power-generation and building insulation: Thermal characteristics and energy consumption prediction
Incidence of circular refurbishment measures on indoor air quality and comfort conditions in two real buildings: Experimental and numerical analysis
Exploring the role of skin temperature in thermal sensation and thermal comfort: A comprehensive review
Investigations of indoor environment of high level biosafety laboratory in China based on field measurements
Optimizing bedroom thermal environment: A review of human body temperature, sleeping thermal comfort and sleep quality
相关作者
Yang Cai
Yingxi Huang
Zhengyu Shu
Ziquan Liu
Huaiyu Zhong
Fuyun Zhao
Valentino Festa
Silvia Ruggiero
相关机构
School of Power and Mechanical Engineering, Wuhan University
School of Energy and Environment, Anhui University of Technology
Energy and Electricity Research Center, Jinan University
Group of Building Environmental Studies-, Physics Department, University of Athens
Department of Architecture - DIARC, University of Naples