针对吉林双辽发电厂300MW机组配套的给水泵前置泵振动过大问题,进行原因综合分析并提出了具体减振措施。经实际处理缺陷后,前置泵振动情况良好。
Over limit booster pump vibration was found in the boiler feed pump units of 300 MW generating set in Shuangliao power plant
Jielin
causes were analysed and specific countermeasures were sugsested. Actual trouble was handled
the booster pump vibration problem was solved.