LIU Wen-qing 1, LIU Wen-tao 2. The Cylinder Flatness Control During Assembly of Steam Turbine 4 in The Harbin Third Power Plant[J]. 2004, (1): 40-41+62.
LIU Wen-qing 1, LIU Wen-tao 2. The Cylinder Flatness Control During Assembly of Steam Turbine 4 in The Harbin Third Power Plant[J]. 2004, (1): 40-41+62.DOI:
哈三电厂4号汽轮机低压缸组合汽缸平面度控制
摘要
为解决哈尔滨第三发电厂 4号机低压缸组合安装中平面度超差问题
在总结 3号机组安装的经验基础上
采取了有效的技术措施和质量控制措施
收到了很好的效果
Abstract
In order to control the flatness deviation to the acceptable level for the low-pressure cylinder assembly of the steam turbine 4 in The Harbin Third Power Plant
the experience obtained from the assembly of steam turbine 3 is applied. In combination with the traditional technology and quality control in the assembly