YAO Wei, QU Guomin, ZHAO Xinglong. Analysis on water wall leakage causes of ultra supercritical boiler[J]. 2016, 36(6): 76-78.DOI:
超超临界锅炉水冷壁泄漏原因分析
摘要
某超超临界锅炉发生水冷壁泄漏。通过对同类型锅炉的调研和此次泄漏原因现场检测及实验分析
查出此次水冷壁泄漏的主要原因是锅炉本身存在不足
调节与控制困难
致使水冷壁管子在中间混合集箱入口区域产生热疲劳
在最薄弱的焊缝熔合线开裂并扩展
导致泄漏。
Abstract
Water wall leakage of a ultral supercritical boiler was occurred in November 2015. In order to find out the causes of this leakage
site inspections and experimental analysis were carefully conducted
together with investigations on the same type boilers in the other thermal power plants. It had been concluded that the design flaws inherent to this type boilers were the main reason for the leakage. Due to difficulties in adjusting and controlling
thermal fatigue occurred at the entrance area of water wall intermediate mixed heads
which then lead cracking and leakage at the weld-fusion line because this area was the weakest site.