[1]吴蔚宇,王小艳,胡沁坤,唐磊.电厂高旁阀振动原因分析及处理[J].湖南电力,2017,37(03):65-67.
WU Weiyu, HU Qinkun, TANG Lei, et al. Analysis and Treatment on Vibration Causes of HP Bypass Valve in Power Plant[J]. 2017, 37(3): 65-67.
[1]吴蔚宇,王小艳,胡沁坤,唐磊.电厂高旁阀振动原因分析及处理[J].湖南电力,2017,37(03):65-67. DOI:
WU Weiyu, HU Qinkun, TANG Lei, et al. Analysis and Treatment on Vibration Causes of HP Bypass Valve in Power Plant[J]. 2017, 37(3): 65-67. DOI:
某电厂在启动过程中
高旁阀出现高频振动造成阀杆振断
通过对振动原因进行综合分析
采取了针对性的处理措施
成功地解决了阀门高频振动问题
消除了安全隐患。
In the process of start-up at a power plant
high frequency vibration of HP bypass valve occurred
and the stem of valve cracked. Through the comprehensive analysis of the causes of vibration
with corresponding measures
the problem of high frequency vibration of HP bypass valve was solved successfully
and the security risk has been eliminated.