ZENG Jun, LI Wenjun, HE Honghao, et al. Experimental Study on the Temperature Deviation of Lower Water Wall in the Ultra Supercritical Boiler[J]. 2017, 37(3): 56-58+82.
ZENG Jun, LI Wenjun, HE Honghao, et al. Experimental Study on the Temperature Deviation of Lower Water Wall in the Ultra Supercritical Boiler[J]. 2017, 37(3): 56-58+82.DOI:
the main factors affecting water wall temperature deviation of lower vertical water wall have been investigated in the 660 MW ultra supercritical boiler. The conclusion indicated that increasing the proportion of high-sodium coal or putting the upper combustors into running can effectively reduce the heat loading in the combustion zone
which benefits uniformity of lower water wall temperature. Through changing the distribution of the heat loading
the angle of combustors has opposite influence on water wall temperature deviation at different load. With optimized adjustments
the wall temperature deviation of vertical water wall in the ultra supercritical boiler can be well controlled.