LIU Liping, HUANG Bo, XIE Jiemin. Treatment and Effect Evaluation of Overcome Vibration of Top Cover of Hydroelectric Unit[J]. 2019, 39(3): 57-59+65.DOI:
The vertical vibration of the head cover has exceeded the national standard since the Baishi hydro-power unit was put into operation
and the problem is dealt with by the method of strengthening the head cover in the power plant. The power plant adopted the method of combining simulation and field measurement to build the head cover model accurately
to successfully predict the natural frequency of the head cover after reinforcement
and avoid the resonance risk caused by the close proximity between the natural frequency of the head cover and the water pressure pulsation in the flow passage
which ensures the successful implementation of the head cover reinforcement scheme. The experimental results after the reinforcement showed that the measured natural frequency was close to the predicted one by simulation
and the vertical vibration of the head cover was obviously improved. Under the test water head
the vertical vibration of the head cover meeted the requirements of the national standard within full load section.