光伏发电技术应用广泛,影响其效率的因素包括太阳辐照强度、光伏电池材料及温度等。因辐照强度受环境影响大,电池材料存在成本、稳定性和技术成熟度等问题,其中控制电池温度是提高效率的实用方法,使用相变材料(phase change material
PCM)冷却是最具前景的温控方式。针对光伏(photovoltaic
PV)-PCM耦合系统的倾斜角度(以下简称为倾角)对电池后面矩形容器内相变材料熔化过程特性的影响和热管理问题,研究了PV-PCM系统倾角对电池板温度和光伏电性能的影响。在太阳辐照强度为600 W/m2、辐照时间为180 min、相变材料厚度为30 mm且基于模拟光源垂直电池板的条件下,试验对比了15°、30°、45°和60°倾角的PV-PCM系统及单光伏板的温度,发现PCM具有降温作用,且电池板工作温度随倾角增大而降低。此外,当PV-PCM系统倾角从15°增至60°时,电池板的最大功率、开路电压、填充因子和最大转化效率随倾角增加而提高,短路电流则随倾角增加而降低。
Photovoltaic power generation technology has widespread applications
with factors affecting its efficiency including solar irradiance intensity
photovoltaic cell materials
and temperature.Since irradiance intensity is highly influenced by environmental conditions
and cell materials face challenges such as cost
stability
and technological maturity
controlling cell temperature emerges as a practical method to enhance efficiency.Using phase change materials(PCM) for cooling represents the most promising temperature control strategy.According to the influence of the inclination angle of the photovoltaic(PV)-PCM coupling system on the melting process characteristics of phase change materials in the rectangular container at the back of the battery and the thermal management issues
it studies the influence of the inclination angle of the PV-PCM system on the temperature of the solar panel and the photovoltaic electrical performance.Under simulated conditions of 600 W/m2 solar irradiance
180 minute irradiation duration
30 mm phase change material thickness
and vertical panel orientation
experiments compare temperatures of PV-PCM systems at 15°
30°
45°and 60° inclination angles against standalone PV panels.Results confirm the cooling effect of phase change materials
with panel operating temperatures decreasing as inclination angle increases.Furthermore
as the inclination angle of the PV-PCM system increased From 15°to 60°
the maximum power output
open-circuit voltage
fill factor
and maximum conversion efficiency of the panels all improve with increasing inclination angle
while the short-circuit current decrease.