There are many mature methods to detect the bearing capacity of single pile
but for high-piled wharf piles
as they are parts of high-piled wharf
and complex structures are built on them
at this stage
for these non-free end piles
there are no effective and feasible bearing capacity detection methods. In this paper
regional heap load method to detect high-piled wharf piles capacity is proposed
and this method doesn’t destroy the original structure. The high-piled wharf piles capacity prototype testing is carried out
and the deformation displacement of while high-piled wharf
the displacement of piles
and the strain of structural elements are tested under grading loads. Also the numerical model is established to analysis the bearing capacity of high-piled wharf piles
and the numerical model is corrected by the experimental results
then the whole prototype test process is simulated using the modified mathematical model. The comparison between the numerical results and the experiment data shows a satisfactory agreement. Through comprehensive analysis
the vertical bearing capacity of high-piled wharf piles is finally determined as 1 400 kN
which could ensure the safety of the high-piled wharf
and the study results could provide experimental basis for the design of the wharf.