Lü Ya-ru, DING Xuan-ming, LIU Han-long, et al. Analysis of pile-soil stress ratio of cast-in-place X-section concrete pile composite foundation under rigid base[J]. 2012, 33(6).
Lü Ya-ru, DING Xuan-ming, LIU Han-long, et al. Analysis of pile-soil stress ratio of cast-in-place X-section concrete pile composite foundation under rigid base[J]. 2012, 33(6).DOI:
pile-soil stress ratio can reflect the load transfer and deformation mechanism of composite foundation. Up to now
as a new pile
no uniform method has been found to calculate the pile-soil stress ratio for X-section pile. Sedimentation basin and filter chamber are typical buildings with concrete floor plate that is considered to be a rigid base. The bearing capacity of pile composite foundation under the rigid base is different from which under the soft base. The in-situ static load tests are carried out based on the foundation treatment project in Qiaobei sewage treatment plant. Besides
a finite element model is built to simulate the cast-in-place X-section concrete pile composite foundation under the rigid base by software ABAQUS. The pile-soil stress ratios are discussed considering some factors including elastic modulus of pile
compression modulus of surrounding soil
pile lengths
cushion thicknesses and compression modulus. The results reveal that the pile-soil stress ratio increases with the increasing of pile modulus
cushion modulus and pile length
while reduces with the increasing of modulus of surrounding soil and cushion thickness. The reasonable pile-soil stress ratio of X-section pile ranges from 20 to 25
corresponding to the pile modulus from 10 to 20 GPa