[Objective] The canned permanent magnet synchronous motor (CPMSM) is widely used in critical fields such as chemical processing
nuclear power
and medical applications due to its high power density
superior efficiency
and excellent dynamic performance. However
research on the impact of batch-produced permanent magnet performance variations on long-term motor stability remains insufficient. Therefore
this study aims to analyze the influence of permanent magnet variations on CPMSM performance and reveal its multi-physics field coupling mechanisms. [Methods] Firstly
a load backs electromotive force-based real-time detection method for permanent magnet magnetic properties was proposed
enabling dynamic post-assembly monitoring without additional sensors. Then
the influence of permanent magnet performance variations on CPMSM electromagnetic fields
temperature distribution
and shield-can thermal stress/deformation was analyzed using finite element models. Finally
experimental validation of the proposed method was subsequently conducted. [Results] The results demonstrated that when compared with the N30-grade
the motor with N38-grade permanent magnets exhibited a 2.56% difference in power factor
a 1.76% difference in efficiency
a 5 ℃ difference in winding temperature
and a 5.82 ℃ difference in casing temperature. [Conclusion] A decline in the magnetic performance of permanent magnets leads to nonlinear deterioration in motor performance metrics
and the performance difference is solely related to the quantity of permanent magnets
independent of their distribution. This study provides theoretical references for the optimized design of CPMSM
the evaluation of permanent magnet deviation impacts
and the enhancement of reliability in harsh environments.