With the construction of a large number of transmission line projects
the proportion of mining-affected areas along the line is increasing day by day. Under the influence of mining activities
the ground surface at the foundation of transmission tower may move and deform
resulting in foundation tilt
tower deformation and other hazards. The hollow protective slab foundation has been successfully applied in miningaffected areas of UHVDC transmission lines
and has achieved good results and engineering application experiences. However
it has a poor adaptability to terrain
huge excavation volume and[JP] serious soil and water loss. Combined with the design experiences of steel members and long and short legs
a connection mode is proposed to move the rigid partition upward and set a new type of adjustable steel pipe truss below the partition surface so as to replace the hollow protective plate foundation
which can effectively improve the towers′ ability to withstand surface deformation and to adapt to the terrain.