Zhang Xiaoteng, Liu Haifeng, Liu Long, et al. Optical diagnosis of n-butanol spray flame in a constant volume combustion chamber[J]. 2025, (5): 423-433.
Zhang Xiaoteng, Liu Haifeng, Liu Long, et al. Optical diagnosis of n-butanol spray flame in a constant volume combustion chamber[J]. 2025, (5): 423-433.DOI:
Based on a self-built optically visualized constant volume combustion chamber system,the effects of injection duration(3.0,6.0,8.6 ms),injection pressure(30,40,50 MPa),and ambient temperature(880, 910,940 K) on n-butanol spray flame were studied. The flame development process and combustion characteristics were revealed by flame self-illumination high-speed imaging method. Results show that the n-butanol spray flame shows a yellow-white flame as a whole,and there is a small amount of light blue flame upstream of the spray. Under small injection duration(3.0 ms),a partial flame-quenching phenomenon presents after n-butanol ignites. As injection duration increases,the soot lift-off length shortens,and the flame brightness,ignition delay and combustion duration increase. As injection pressure increases,the flame brightness and flame backtracking phenomenon weaken,and the soot lift-off length increases. At the same time,the ignition delay is prolonged,but the combustion duration is shortened. The ambient temperature has a significant effect on the stable ignition of nbutanol spray flame. With an increase in ambient temperature of only 60 K,the ignition delay of n-butanol spray flame is notably shortened by 4.16 ms,while the flame brightness is obviously enhanced and the flame shape is more stable