A high arch dam is located in an alpine valley with complex hydrogeological conditions. After impoundment
significant seepage has occurred in multiple drainage holes of the drainage tunnel of dam foundation on the left bank
which is a key concern of the project. To identify the cause of the seepage
based on the hydrogeological conditions during impoundment
seepage control and treatment measures
pseudo-random flow field method detection results
monitoring and inspection results
combined with nearly 10-year monitoring data under the 80 m cycle of reservoir water level fluctuation
a comprehensive analysis is conducted on the characteristics of seepage and seepage pressure in the drainage tunnel and behind the curtain
as well as the source of seepage. The results indicate that the curtain in dam foundation of the left bank is effective
the seepage and seepage pressure have decreased year by year and tend to stabilize
and the seepage volume is much smaller than the design pumping and drainage capacity of the dam foundation drainage well. The seepage mainly comes from mountain groundwater and downstream river water