The uplift pressure and seepage volume are the most intuitive reflection of the foundation seepage behavior of concrete gravity dam. To get the general variation of the foundation uplift pressure and seepage volume of the gravity dam during operation period
the monitoring data of the main concrete gravity dams in domestic power industry are analyzed. The results show that it is a common phenomenon that the uplift pressure coefficient of partial foundation of the gravity dam exceeds the design value. However
due to the large safety margin in design
the anti-sliding stability of dam foundation could still meet the specification requirements in review and calculation. Under normal conditions
the foundation seepage volume of gravity dam is not greater than 5.0 L/s. The seepage flow of dam foundation of different projects is closely related to geological conditions
seepage control effect and earthquake
but has a weak correlation with dam height or dam crest length. The study results could provide some reference for monitoring data analysis and seepage safety evaluation of concrete gravity dams.